Skip to main content

Genome-wide scans using archived neonatal dried blood spot samples.

Hollegaard MV, Grauholm J, Børglum A, Nyegaard M, Nørgaard-Pedersen B, Ørntoft T, Mortensen PB, Wiuf C, Mors O, Didriksen M, Thorsen P, Hougaard DM

Publication: BMC Genomics (2009) • Vol 10 • Page 297PMID: 19575812View on PubMed

Purpose

The purpose of this paper was to determine the effects of DNA extraction and whole genome amplification (WGA) method on genome-wide analysis of archival dried blood spots (DBS).

Conclusion

Extraction of DNA from DBS with Extract-N-Amp blood PCR kit (ENA) followed by amplification with Repli-g resulted in the highest average call rate and the lowest call conflict with fresh reference DNA from venous blood specimens. Using 3 disks for DNA extraction instead of 1 did not improve call rates or decrease conflict rates. Further, the age of the DBS (15-25 y) had no significant effects on genotyping performance.

Studies (1)

Purpose

The purpose of this study was to determine the effects of storage duration of DBS, DNA extraction method, and WGA method on genome-wide analysis of archival DBS from volunteers and neonates enrolled in a genetic schizophrenia study. DBS from 24 neonates were stored for 15-25 years at -24 degrees C. DNA was extracted from 1 or 3 3.2 mm disks with ENA or QIAamp DNA blood micro kit (QIAamp), amplified using one of 3 different WGA kits, and hybridized to Illumina Infinium HD Human610-Quad BeadChips. Results were compared to those obtained using DNA extracted from venous blood with the Maxwell 16 DNA purification system.

Summary of Findings

Extraction of DNA from DBS with ENA followed by amplification with Repli-g resulted in the highest average call rate (>99%) and the lowest call conflict with fresh reference DNA from venous blood specimens (0.02-0.03%). When DNA was extracted with QIAamp, amplification with REPLI-g led to high variability in call and conflict rates, but amplification with GenomePlex Single Cell whole genome amplification kit led to >97% call rates and less than 0.038% conflict with the reference DNA. Using 3 disks for DNA extraction instead of 1 did not improve call rates or decrease conflict rates. Further, the storage duration of DBS had no significant effects on genotyping performance.

  • Biospecimens

    FluidBlood
  • Preservation Types

    Other PreservativeNone (Fresh)
  • Diagnoses

    Not specified
    Schizophrenia
  • Platforms

    DNADNA microarray
    DNAFluorometry
    DNAWhole genome amplification
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen Aliquots and ComponentsAliquot size/volume
    1 x 3.2 mm disk
    3 x 3.2 mm disk
    Biospecimen PreservationType of fixation/preservation
    Air-dried
    None (fresh)
    StorageStorage duration
    15-25 years
    Analyte Extraction and PurificationAnalyte isolation method
    Extract-N-Amp blood PCR kit
    Maxwell 16 DNA purification system
    QIAamp DNA blood micro kit
    Whole genome amplification SpecificNucleic acid amplification
    GenomePlex Complete WGA kit (GPlex2))
    GenomePlex Single Cell whole genome amplification kit (GPLex4)
    Qiagen REPLI-g kit