Comparison of laboratory values obtained by phlebotomy versus saline lock devices.

Corbo J, Fu L, Silver M, Atallah H, Bijur P

Publication: Acad Emerg Med (2007) • Vol 14 • Page 23-7PMID: 17099189View on PubMed

Purpose

The purpose of this paper was to determine the effects of obtaining blood specimens through a saline lock device (SLD) as opposed to venipuncture on hematocrit, electrolytes, glucose, and cardiac enzyme levels.

Conclusion

The overall success rate of obtaining specimens from the SLD was 90.1%. No clotted or hemolyzed specimens were obtained using SLD or standard venipuncture for specimen collection. There were no statistically significant differences in the mean values of any of the tested analytes between the two collection methods.

Studies (1)

Purpose

The purpose of this study was to determine the effects of obtaining blood specimens through an SLD as opposed to venipuncture on hematocrit, electrolytes, glucose, and cardiac enzyme levels. The effects of catheter size on successful aspiration were also examined. SLD specimens were obtained within 5 minutes of venipuncture specimens, and the first 5 mL of blood obtained through the SLD was discarded.

Summary of Findings

While the overall success rate of obtaining specimens from the SLD was 90.1%, there appeared to be a decline in success rates with increasing catheter gauge, however, sample size was highly varied among the catheter gauges analyzed, and some samples were too small for statistical analysis. No clotted or hemolyzed specimens were obtained using SLD or standard venipuncture for specimen collection. While there were no statistically significant differences in the mean values of any of the tested analytes (hematocrit, serum sodium, potassium, chloride, bicarbonate, glucose, creatine phosphokinase, and troponin I) between the two collection methods, 6.0% of the paired values analyzed exceeded the Bland-Altman limits of agreement, and, with venipuncture taken as the standard, 7.4% of the values obtained from SLD specimens were outside the national recommended Clinical Laboratory Improvement Amendment (CLIA) range. Importantly, the authors state that none of the values exceeding Bland-Altman limits of agreement would have warranted clinical intervention.
  • Biospecimens

    FluidBlood
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Not specified
  • Platforms

    CarbohydrateClinical chemistry/auto analyzer
    Electrolyte/MetalClinical chemistry/auto analyzer
    Small moleculeClinical chemistry/auto analyzer
    ProteinClinical chemistry/auto analyzer
    Cell count/volumeHematology/ auto analyzer
    Cell count/volumeMacroscopic observation
    MorphologyMacroscopic observation
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionCannulation
    18-gauge catheter
    20-gauge catheter
    22-gauge catheter
    Biospecimen AcquisitionMethod of fluid acquisition
    Saline lock device
    Venipuncture