Diversion of first blood volume results in a reduction of bacterial contamination for whole-blood collections.

de Korte D, Marcelis JH, Verhoeven AJ, Soeterboek AM

Publication: Vox Sang (2002) • Vol 83 • Page 13-6PMID: 12100383View on PubMed

Purpose

The purpose of this paper was to determine the effects of inclusion of the first 10 mL of blood collected on the presence of bacterial contamination in donated blood.

Conclusion

When the first 10 mL of blood was included, the bacterial contamination rate was 0.35%. When the first 10 mL of blood was collected in a separate vacutainer, the remaining blood donations had a bacterial contamination rate that was significantly lower (0.21%).

Studies (1)

Purpose

The purpose of this study was to determine the effects of inclusion of the first 10 mL of blood collected on the presence of bacterial contamination in donated blood. Butane-diol plates were used to rapidly cool specimens to 20 degrees C for 2-14 h before culturing began. Blood was incubated for 7 days at 35 degrees C or until positive for bacterial contamination.

Summary of Findings

When the first 10 mL of blood was included in the specimen, the bacterial contamination rate was 0.35%. When the first 10 mL of blood was collected in a separate vacutainer, the remaining blood donations had a bacterial contamination rate that was significantly lower (0.21%, P<0.05).
  • Biospecimens

    FluidBlood
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Not specified
  • Platforms

    Cell count/volumeMicrobiological assay
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen Aliquots and ComponentsAliquot sequential collection
    1st collection
    2nd collection