Efficacy of a new collection procedure for preventing bacterial contamination of whole-blood donations.

Bruneau C, Perez P, Chassaigne M, Allouch P, Audurier A, Gulian C, Janus G, Boulard G, De Micco P, Salmi LR, Noel L

Publication: Transfusion (2001) • Vol 41 • Page 74-81PMID: 11161249View on PubMed

Purpose

The purpose of this paper was to determine the effects of discarding the first 15 mL of a blood specimen on the rates of bacterial contamination.

Conclusion

In 2.2% of cases (76/3385), the first and/or second 15 mL aliquot of blood drawn was contaminated with bacteria. The second 15 mL aliquot of blood drawn cultured positive for bacteria in 0.6% of cases (21/3385), effectively reducing the bacterial contamination risk if the first 15 mL of blood collected were to be thrown out.

Studies (1)

Purpose

The purpose of this study was to determine the effects of discarding the first 15 mL of a blood specimen on the rates of bacterial contamination.

Summary of Findings

In 2.2% of cases (76/3385), the first and/or second 15 mL aliquot of blood drawn was contaminated with bacteria. The second 15 mL aliquot of blood drawn cultured positive for bacteria in 0.6% of cases (21/3385), effectively reducing the bacterial contamination risk if the first 15 mL of blood collected were to be thrown out.
  • Biospecimens

    FluidBlood
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Not specified
  • Platforms

    Cell count/volumeLight microscopy
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen Aliquots and ComponentsAliquot sequential collection
    1st collection
    2nd collection