Implementation of a pneumatic-tube system for transport of blood specimens.

Poznanski W, Smith F, Bodley F

Publication: Am J Clin Pathol (1978) • Vol 70 • Page 291-5PMID: 696689View on PubMed

Purpose

The purpose of this paper was to determine the effects of pneumatic tube system (PTS) transport, tube fill volume, anticoagulation with heparin, and clotting prior to transport on clinical chemistry analytes in blood.

Conclusion

For specimens collected with no anticoagulant, total carbon dioxide (CO2) and chloride (Cl-) were slightly increased in specimens transported by PTS rather than hand-delivered. PTS transport rather than hand-delivery did not affect potassium (K+), hemoglobin, or lactate dehydrogenase (LDH) when the collection tubes were half-filled or contained heparin, but LDH was increased in clotted blood that was sent by PTS rather than hand-delivered.

Studies (1)

Purpose

The purpose of this study was to determine the effects of PTS transport, tube fill volume, anticoagulation with heparin, and clotting prior to transport on clinical chemistry analytes in blood. Blood was obtained from patients in the emergency room or intensive care unit and transported immediately or allowed to clot for 15 min prior to transport. For blood gas analysis the specimens were wrapped in a cold pack prior to immediate transport.

Summary of Findings

CO2 and Cl- were slightly increased in specimens transported by PTS rather than hand-delivered. Transport method did not affect K+, hemoglobin, or LDH when collection tubes were half-filled or when they contained heparin, but LDH was increased in clotted blood that was sent by PTS rather than hand-delivered. For unclotted specimens collected with no anticoagulant, glucose, urea, sodium, K+, LDH, hemoglobin, pH, partial pressure oxygen (PO2), and partial pressure carbon dioxide (PCO2) were unaffected by transport method.
  • Biospecimens

    FluidBlood
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Not specified
  • Platforms

    CarbohydrateClinical chemistry/auto analyzer
    Electrolyte/MetalClinical chemistry/auto analyzer
    ProteinClinical chemistry/auto analyzer
    GasClinical chemistry/auto analyzer
    Small moleculeClinical chemistry/auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionAnticoagulant
    Heparin
    None
    Biospecimen Aliquots and ComponentsAliquot size/volume
    Filled vacutainer
    Half-filled vacutainer
    StorageSpecimen transport duration/condition
    Clotted
    Unclotted
    StorageWithin hospital transportation method
    Hand-delivered
    Pneumatic tube system