A computer directed pneumatic tube system: its effects on specimens.
Pragay DA, Fan P, Brinkley S, Chilcote ME
Purpose
The purpose of this paper was to determine the effects of pneumatic tube system (PTS) transport on clinical chemistry analytes in blood and urine specimens.
Conclusion
Lactate dehydrogenase (LD) was elevated in blood specimens from healthy individuals and patients with pulmonary diseases, cardiac problems and gastrointestinal diseases after being transported by dedicated or general PTS compared to hand-delivered specimens, but elevations were not significant for patients with neoplastic diseases. The authors report that sending clotted versus unclotted blood through the PTS did not significantly affect any analyte, and PTS transport did not affect urinary casts.
Studies (2)
Purpose
The purpose of this study was to determine the effects of PTS transport on 3 clinical chemistry and 3 gas analytes in blood specimens. Specimens were placed in a ziplock bag and towel wrapped before transport via a dedicated PTS or placed in a plastic bag inside a carrier with a foam insert before transport via a general PTS.
Summary of Findings
LD was elevated in blood specimens from healthy individuals after being transported by dedicated or general PTS compared to specimens that were hand-delivered (p<0.001 and p<0.01, respectively). The authors report the increase in LD after PTS transport was due to small increases in LD fractions 1, 2 and 3. LD was also elevated after PTS transport in patients with pulmonary diseases (p<0.001), cardiac problems (p<0.001) and gastrointestinal diseases (p<0.05), but not in patients with neoplastic diseases. The authors report that sending clotted versus unclotted blood through the PTS did not significantly affect any analyte. PTS transport did not affect blood potassium, partial pressure carbon dioxide (PCO2), partial pressure oxygen (PO2), pH, or acid phosphatase.
Biospecimens
FluidBloodPreservation Types
None (Fresh)Diagnoses
Cardiovascular DiseaseNeoplasticNormalOther diagnosesPlatforms
Electrolyte/MetalFlame emission photometryProteinClinical chemistry/auto analyzerGasClinical chemistry/auto analyzerSmall moleculepHPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Preaquisition Diagnosis/ patient condition Cardiac problemsGastrointestinal diseasesNeoplastic diseasesNormalPulmonary diseasesStorage Specimen transport duration/condition ClottedIn a ziplock bag in a carrier with a foam insertIn ziplock bag and wrapped in a towelNot clottedStorage Within hospital transportation method Hand-deliveredPneumatic tube system
Purpose
The purpose of this study was to determine the effects of PTS transport on urinary casts.
Summary of Findings
The authors report that PTS transport did not affect urinary casts compared to urine specimens that were hand-delivered.
Biospecimens
FluidUrinePreservation Types
None (Fresh)Diagnoses
Not specifiedPlatforms
MorphologyLight microscopyPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Storage Within hospital transportation method Hand-deliveredPneumatic tube system