Skip to main content

Impact of evacuated collection tube fill volume and mixing on routine coagulation testing using 2.5-ml (pediatric) tubes.

Chuang J, Sadler MA, Witt DM

Publication: Chest (2004) • Vol 126 • Page 1262-6PMID: 15486391View on PubMed

Purpose

The purpose of this paper was to determine the effects of specimen mixing and tube fill volume on international normalized ratio (INR) results derived from prothrombin time (PT) in specimens from patients on warfarin anticoagulation therapy and healthy volunteers.

Conclusion

Neither the number of tube inversions after specimen collection (1-5) nor the duration of time before mixing (0-4 min) had significant effects on mean INR in healthy volunteers or patients receiving warfarin. However, INRs were significantly higher in specimens from healthy volunteers and patients on warfarin when tubes were filled <90% compared to tubes that were 100% full.

Studies (1)

Purpose

The purpose of this study was to determine the effects of specimen inversion, time prior to specimen mixing, and tube fill volume on INR results derived from PT in specimens from patients on warfarin anticoagulation therapy and healthy volunteers. Plasma was frozen at -20 degrees C until analysis.

Summary of Findings

Neither the number of tube inversions after specimen collection (1-5) nor the duration of time before mixing (0-4 min) had significant effects on mean INR in healthy volunteers or patients receiving warfarin. However, fill volumes of <90% lead to significantly higher INRs compared to tubes that were 100% full for specimens from healthy volunteers (after elimination of 3 outliers) and patients on warfarin (p<0.01 and p<0.001, respectively).

  • Biospecimens

    FluidPlasma
    FluidBlood
  • Preservation Types

    Frozen
  • Diagnoses

    Cardiovascular Disease
    Normal
    Other diagnoses
  • Platforms

    MorphologyHematology/ auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    PreaquisitionDiagnosis/ patient condition
    Stroke/cerebrovascular accident
    PreaquisitionOther drugs
    Aspirin
    None
    Warfarin
    Biospecimen Aliquots and ComponentsAliquot size/volume
    100% full
    50% full
    60% full
    70% full
    80% full
    90% full
    Biospecimen Aliquots and ComponentsBiospecimen mixing
    After 0 min
    After 1 min
    After 2 min
    After 3 min
    After 4 min
    Inverted five times
    Inverted four times
    Inverted once
    Inverted three times
    Inverted twice