Skip to main content

Stability of novel plasma markers associated with cardiovascular disease: processing within 36 hours of specimen collection.

Pai JK, Curhan GC, Cannuscio CC, Rifai N, Ridker PM, Rimm EB

Publication: Clin Chem (2002) • Vol 48 • Page 1781-4PMID: 12324497View on PubMed

Purpose

The purpose of this paper was to determine the effects of storage of whole blood in a cold shipping container on plasma levels of markers associated with cardiovascular disease.

Conclusion

Lipoprotein a (Lp a), fibrinogen, tumor necrosis factor receptor -I (TNF-RI), p-selectin, von Willebrand factor (vWf), and matrix metalloproteinase -1 (MMP-1) were significantly affected by storage for up to 36 h, in a styrofoam container, on a cold pack. Further, the reliability of measurement of vascular cell adhesion molecule -1 (VCAM-1), fibrinogen, p-selectin, MMP-1 and vWF were reduced after storage.

Studies (1)

Purpose

The purpose of this study was to determine the effects of storage of sodium heparinated whole blood in a shipping container with a cold pack on markers associated with cardiovascular disease. After experimental storage, plasma was aliquoted and stored in liquid nitrogen until analysis.

Summary of Findings

C-reactive protein (CRP), apolipoprotein B (apoB), oxidized low density lipoprotein (oxLDL), intracellular cell adhesion molecule -1 (ICAM-1), VCAM-1, TNF-RII, and anti-cardiolipin antibodies (aCLAbs) were not affected by storage for up to 36 h, in a styrofoam container, on a cold pack. Lp a and fibrinogen declined after 36 h of storage. TNF-RI and p-selectin increased with longer times to processing, reaching significance at 36 and 24 h, respectively. vWf decreased significantly after 24 h and increased significantly after 36 h compared to baseline. MMP-1 was significantly increased at 24 h and significantly decreased at 36 h compared to baseline. After storage, the reliability of measurement of VCAM-1 was good, the reliability of fibrinogen was poor (24 h) to fair (36 h), and the reliabilities of p-selectin, MMP-1 and vWF were poor, but all other analytes displayed excellent reliability after storage.

  • Biospecimens

    FluidBlood
    FluidPlasma
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Not specified
  • Platforms

    GlycoproteinClinical chemistry/auto analyzer
    ProteinClinical chemistry/auto analyzer
    ProteinELISA
    LipidClinical chemistry/auto analyzer
    SteroidClinical chemistry/auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen Aliquots and ComponentsCentrifugation
    Centrifugation delays investigated
    StorageStorage duration
    0 h
    24 h
    36 h