Evaluation of a soft-handling computerized pneumatic tube specimen delivery system. Effects on analytical results and turnaround time.
Keshgegian AA, Bull GE
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine the effects of transporting specimens by PTS with a soft-handling feature on 3 blood gas, 17 clinical chemistry and 9 hematological analytes. Specimens were collected in duplicate into appropriate tubes (serum separator clot, EDTA, lithium heparin, microtainer plasma) or syringes based on analyte. One tube was sent via PTS while the duplicate was hand-delivered.
Summary of Findings
The hematocrit in blood from infants in NICU was significantly lower (0.3942 versus 0.3955) when the blood was transported by PTS rather than courier (p=0.025) but a similar decrease in the hematocrit was not observed after PTS transport of blood from adult patients in the outpatient clinic. No other analytes were affected by transport via PTS rather than hand-delivery, but mean turnaround time for hemoglobin and potassium results were decreased by 55% when specimens were transport by PTS instead of hand-delivery.
Biospecimens
FluidBloodFluidPlasmaFluidSerumPreservation Types
None (Fresh)Diagnoses
Not specifiedCardiovascular DiseaseOther diagnosesPlatforms
CarbohydrateClinical chemistry/auto analyzerCell count/volumeHematology/ auto analyzerElectrolyte/MetalClinical chemistry/auto analyzerGasClinical chemistry/auto analyzerProteinClinical chemistry/auto analyzerProteinHematology/ auto analyzerSmall moleculeClinical chemistry/auto analyzerSmall moleculepHPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Preaquisition Diagnosis/ patient condition Adult outpatientIntraoperative cardiac surgery patientNICU patientStorage Within hospital transportation method Hand-deliveredPneumatic tube system