Effect of phlebotomy technique on serum bicarbonate values.

Berns SD, Matchett JL

Publication: Acad Emerg Med (1998) • Vol 5 • Page 40-4PMID: 9444341View on PubMed

Purpose

The purpose of this paper was to determine the effects of needle gauge, tourniquet time, and tube fill volume on bicarbonate levels, partial pressure carbon dioxide (pCO2), pH, and lactate levels in serum.

Conclusion

There were no significant differences in serum bicarbonate levels between specimens obtained using a 20-gauge needle rather than a 24-gauge needle. Significantly elevated bicarbonate, pCO2, and lactate were measured in specimens acquired after prolonged tourniquet time while the pH was significantly decreased in these specimens compared to specimens drawn immediately following tourniquet placement. Underfilling Vacutainer tubes (<4 mL) resulted in significantly reduced serum bicarbonate values compared to those in specimens from filled tubes, but there were no differences in bicarbonate values between specimens that were transferred to tubes using a 20-gauge needle and those transferred by syringe with Vacutainer cap removed.

Studies (1)

Purpose

The purpose of this study was to determine the effects of needle gauge, tourniquet time, and tube fill volume on bicarbonate levels, pCO2, pH, and lactate levels in serum. Specimens intended for the tourniquet time study were placed on ice until analysis (within 1 hour of collection) while other specimens were analyzed immediately.

Summary of Findings

There were no significant differences in serum bicarbonate levels between specimens obtained using a 20-gauge needle rather than a 24-gauge needle. Significantly elevated bicarbonate, pCO2, and lactate were measured in specimens acquired after prolonged tourniquet time while the pH was significantly decreased in these specimens compared to specimens drawn immediately following tourniquet placement. Underfilling Vacutainer tubes (<4 mL) resulted in significantly reduced serum bicarbonate values compared to those in specimens from filled tubes, but there were no differences in bicarbonate values between specimens that were transferred to tubes using a 20-gauge needle and those transferred by syringe with Vacutainer cap removed.

  • Biospecimens

    FluidSerum
    FluidBlood
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Normal
  • Platforms

    Electrolyte/MetalClinical chemistry/auto analyzer
    Small moleculeClinical chemistry/auto analyzer
    GasClinical chemistry/auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionMethod of fluid acquisition
    Tourniquet times compared
    Biospecimen AcquisitionNeedle gauge
    20-gauge
    24-gauge
    Use of syringe for transfer to tube
    Biospecimen Aliquots and ComponentsAliquot size/volume
    0.5 mL
    1 mL
    2 mL
    3 mL
    4 mL