Skip to main content

Effects of a pneumatic tube system on routine and novel hematology and coagulation parameters in healthy volunteers.

Kratz A, Salem RO, Van Cott EM

Publication: Arch Pathol Lab Med (2007) • Vol 131 • Page 293-6PMID: 17284116View on PubMed

Purpose

The purpose of this paper was to determine the effects of pneumatic tube system (PTS) transport on hematological and coagulation parameters in blood.

Conclusion

Transport of specimens by PTS rather than by hand-delivery did not affect complete blood counts (CBCs), white blood cell differentials, prothrombin time (PT), activated partial thromboplastin time (APTT), levels of fibrinogen or fibrin monomers, or erythrocyte sedimentation rate (ESR). The average mean platelet component concentration (MPC) was slightly higher in PTS-transported specimens than in hand-delivered specimens, but only 18 of the 33 specimens had higher MPC after PTS transport compared to hand-delivery.

Studies (1)

Purpose

The purpose of this study was to determine the effects of PTS transport on hematological and coagulation parameters in blood. Cell counts were obtained from potassium-EDTA anticoagulated blood within 1 h of venipuncture. Citrated blood was centrifuged and plasma was analyzed for coagulation parameters within 2 h or was frozen at -70 degrees C until analysis for coagulation assays.

Summary of Findings

Transport of specimens by PTS rather than by hand-delivery did not affect CBCs, white blood cell differentials, PT, APTT, levels of fibrinogen or fibrin monomers, or ESR. The average MPC was slightly higher (28.1 versus 28.2 g/dL) in PTS-transported specimens than in hand-delivered specimens, but this difference was only significant when the two specimens from individuals taking aspirin were excluded (p=0.04). While 18 specimens had higher MPC after PTS transport than after hand-delivery, 10 specimens showed lower MPC after PTS transport, and 5 had the same MPC after PTS transport as after hand-delivery.

  • Biospecimens

    FluidBlood
    FluidPlasma
  • Preservation Types

    None (Fresh)Frozen
  • Diagnoses

    Normal
  • Platforms

    Cell count/volumeHematology/ auto analyzer
    GlycoproteinHematology/ auto analyzer
    MorphologyHematology/ auto analyzer
    ProteinClinical chemistry/auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen PreservationType of fixation/preservation
    Frozen
    None (fresh)
    StorageWithin hospital transportation method
    Hand-delivered
    Pneumatic tube system