Comparability of venous and capillary glucose measurements in blood.
Colagiuri S, Sandbaek A, Carstensen B, Christensen J, Glumer C, Lauritzen T, Borch-Johnsen K
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine the effects of measuring glucose in venous plasma versus capillary whole blood from patients after fasting, 2 h post glucose consumption, or from non-selected patients. Two capillary specimens were obtained from two different sites and two venous specimens were obtained from a single venipuncture. Venous plasma was collected in tubes containing heparin and sodium fluoride.
Summary of Findings
Glucose levels in capillary specimens had the smallest analytical variance when collected from fasting individuals and largest variance when collected 2 h after glucose consumption. Venous plasma collected randomly or after fasting had consistently higher glucose levels than capillary whole blood collected at equivalent times, but specimens collected 2 h post glucose consumption had lower glucose levels than capillary whole blood also collected post glucose consumption.
Biospecimens
FluidBloodFluidPlasmaPreservation Types
None (Fresh)Diagnoses
Not specifiedPlatforms
CarbohydrateClinical chemistry/auto analyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Anatomical location of blood draw CapillaryVeinBiospecimen Acquisition Time of biospecimen collection 2 h after oral glucose consumptionAfter fastingRandomBiospecimen Aliquots and Components Blood and blood products PlasmaWhole blood