Evaluation of a pneumatic-tube system for delivery of blood specimens to the blood bank.
Bruner KW Jr, Kissling CW
Purpose
The purpose of this paper was to determine the effects of pneumatic tube system (PTS) transport on the determination of blood type and crossmatch.
Conclusion
Transportation method did not significantly affect blood type or crossmatch, but the authors report slight but visible hemolysis in PTS transported specimens that was not observed in the hand delivered specimens. The authors report that the titers and scores were the same when the tubes were only one third full as when they were nearly full.
Studies (1)
Purpose
The purpose of this study was to determine the effects of PTS transport on the determination of blood type and crossmatch.
Summary of Findings
Transportation method did not significantly affect blood type or crossmatch, but the authors report slight but visible hemolysis in PTS transported specimens that was not observed in the hand delivered specimens. The authors report that the titers and scores were the same when the tubes were only one third full as when they were nearly full.
Biospecimens
FluidBloodPreservation Types
None (Fresh)Diagnoses
Not specifiedPlatforms
ProteinHematology/ auto analyzerMorphologyMacroscopic observationPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Aliquots and Components Aliquot size/volume 1/3 fullNearly fullStorage Within hospital transportation method Hand-deliveredPneumatic tube system