Influence of separator gel in Sarstedt S-Monovette® serum tubes on various therapeutic drugs, hormones, and proteins.
Schouwers S, Brandt I, Willemse J, Van Regenmortel N, Uyttenbroeck W, Wauters A, Neels H
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine the effects of collection and storage of serum in Sarstedt S-Monovette tubes with separator gel on monitoring of therapeutic drugs and the measurement of selected common hormones and proteins. Serum collected in tubes containing separator gel was stored on the gel at 4 degrees C until analysis, while serum collected in tubes without gel separator was transferred to new polystyrene tubes for storage.
Summary of Findings
No statistically significant differences were observed for any analyte (amikacin, vancomycin, valproic acid, acetaminophen, cortisol, free thyroxine, thyroid-stimulating hormone, transferrin, prealbumin, and carcinoembryonic antigen) between specimens collected in plain and gel separator tubes when analysis was performed within 2 hours of collection. However, after storage of serum at 4 degrees C on the gel, all analytes except valproic acid and acetaminophen were significantly higher in serum in the tubes containing the gel separator than in serum that had been transferred from tubes without gel separator to new polystyrene tubes. Stability analysis of the analytes revealed that amikacin, vancomycin, and acetaminophen were generally stable for up to 72 h in serum collected in either type of tube. Valproic acid and thyroid-stimulating hormone proved to be unstable during storage of serum in gel separator tubes but not in tubes without gel separator, and cortisol, free thyroxine, transferrin, prealbumin, and carcinoembryonic antigen were unstable during storage in either type of tube. All of these statistically significant changes were clinically irrelevant, with the exception of the increases in free thyroxine and transferrin during storage at 4 degrees C, in either type of tube, after 24-48 h.
Biospecimens
FluidSerumFluidBloodPreservation Types
None (Fresh)Other PreservativeDiagnoses
Not specifiedPlatforms
GlycoproteinClinical chemistry/auto analyzerSmall moleculeClinical chemistry/auto analyzerSteroidClinical chemistry/auto analyzerPeptideClinical chemistry/auto analyzerProteinClinical chemistry/auto analyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Type of collection container/solution Plain Sarstedt S-Monovette tubesSarstedt S-Monovette tubes with separator gelBiospecimen Preservation Type of fixation/preservation None (fresh)RefrigerationStorage Storage duration 24 h48 h72 h<2 h