Skip to main content

An episode of increased hemolysis due to a defective pneumatic air tube delivery system.

Ellis G

Publication: Clin Biochem (2009) • Vol 42 • Page 1265-9PMID: 19445913View on PubMed

Purpose

The purpose of this paper was to determine the effects of transfer via a pneumatic tube system (PTS) on potassium levels and hemolysis in blood specimens.

Conclusion

Transport of specimens by PTS led to increases in the percentage of hemolysed specimens, mean hemolysis index (HI) and potassium levels. This effect was exacerbated when the PTS was defective and partially attenuated by wrapping the specimens in bubble wrap.

Studies (1)

Purpose

The purpose of this study was to determine the effects of transport via a pneumatic tube system (PTS) on potassium levels and hemolysis in blood specimens. The effects of a defective PTS system caused by a kink that did not prevent tube passage and bubble wrapping prior to transport were also investigated.

Summary of Findings

Prior to installation of the PTS system 3.3% of specimens were hemolysed, but after installation of the PTS, this rose to 10.9%. Further, a clinically insignificant rise in the serum potassium of the non-hemolyzed specimens was detected (4.08 mmol/L to 4.16 mmol/L, p<0.001). When the system became defective, hemolysis increased to 54%. But subsequently, hemolysis decreased to 9% after system repair and was further decreased to 7.1% by wrapping the specimens in bubble wrap; however, this was significantly above the 3.3% rate achieved by use of porters (p<0.0001) in the same ward or the 4.1% hemolysis rate achieved in other wards using porters. The daily mean hemolysis index (HI) showed trends similar to the percentage of hemolysed specimens.
  • Biospecimens

    FluidBlood
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Not specified
  • Platforms

    MorphologyHematology/ auto analyzer
    Electrolyte/MetalClinical chemistry/auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    StorageSpecimen transport duration/condition
    Bubble wrap prior to transfer via pneumatic tube system
    Standard cartridge only
    Transfer in defective pneumatic tube system
    StorageWithin hospital transportation method
    Hand-delivered
    Pneumatic tube system