Skip to main content

Collection tubes with or without gel separator did not interfere with detection of rubella virus antibodies IgM and IgG.

Oliveira LC, Kawasato KH, Otta MS, Lima LP, Okay TS

Publication: J Clin Lab Anal (2007) • Vol 21 • Page 330-4PMID: 17847106View on PubMed

Purpose

The purpose of this paper was to determine the effects of collecting blood specimens in tubes with gel separators on the detection of rubella virus antibodies in serum from children.

Conclusion

There were no significant differences in the detection of rubella antibodies between Vacuette and Vacutainer tubes with or without gel separators.

Studies (1)

Purpose

The purpose of this study was to determine the effects of collecting blood specimens in tubes with gel separators on the detection of rubella virus antibodies in serum from children. After centrifugation, serum from tubes without gel was transferred to clean glass storage tubes while serum was left in primary tubes containing gel. Serum specimens were kept refrigerated at 4 degrees C for 48 h until analysis.

Summary of Findings

There were no significant differences in the detection of rubella antibodies (IgG or IgM) between Vacuette and Vacutainer tubes with or without gel separators.

  • Biospecimens

    FluidSerum
    FluidBlood
  • Preservation Types

    Other Preservative
  • Diagnoses

    Normal
  • Platforms

    GlycoproteinImmunoassay
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionType of collection container/solution
    Vacuette Bio-one with gel
    Vacuette Bio-one without gel
    Vacutainer with gel
    Vacutainer without gel
    Immunoassay SpecificTargeted peptide/protein
    IgG
    IgM