Collection tubes with or without gel separator did not interfere with detection of rubella virus antibodies IgM and IgG.
Oliveira LC, Kawasato KH, Otta MS, Lima LP, Okay TS
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine the effects of collecting blood specimens in tubes with gel separators on the detection of rubella virus antibodies in serum from children. After centrifugation, serum from tubes without gel was transferred to clean glass storage tubes while serum was left in primary tubes containing gel. Serum specimens were kept refrigerated at 4 degrees C for 48 h until analysis.
Summary of Findings
There were no significant differences in the detection of rubella antibodies (IgG or IgM) between Vacuette and Vacutainer tubes with or without gel separators.
Biospecimens
FluidSerumFluidBloodPreservation Types
Other PreservativeDiagnoses
NormalPlatforms
GlycoproteinImmunoassayPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Type of collection container/solution Vacuette Bio-one with gelVacuette Bio-one without gelVacutainer with gelVacutainer without gelImmunoassay Specific Targeted peptide/protein IgGIgM