A comparison of glass and plastic blood collection tubes for routine and specialized coagulation assays: a comprehensive study.
Kratz A, Stanganelli N, Van Cott EM
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine the effects of using plastic versus glass blood collection tubes on 22 different coagulation assays in plasma. Some specimens were analyzed immediately after processing while others were stored at -70 degrees C until analysis.
Summary of Findings
14 of the 22 coagulation assays showed no statistical differences between specimens collected in glass BD Vacutainer tubes and plastic BD Vacutainer Plus tubes. The tests that did show a statistically significant difference between tube types included fibrinogen, protein C activity, Factor X, Factor XI, and Factor XII which were increased in plastic tubes compared to glass tubes, and protein S activity, lupus anticoagulant, and Factor VII which were decreased in plastic tubes compared to glass tubes. These assays had average differences of 0.4%-5.5% between tube types, and the authors state they are unlikely to be clinically significant.
Biospecimens
FluidPlasmaFluidBloodPreservation Types
None (Fresh)FrozenDiagnoses
NormalPlatforms
ProteinHematology/ auto analyzerMorphologyHematology/ auto analyzerGlycoproteinHematology/ auto analyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Type of collection container/solution Glass Vacutainer tubesPlastic Vacutainer Plus tubesBiospecimen Preservation Type of fixation/preservation FrozenNone (fresh)