Skip to main content

Suitability of collection tubes with separator gels for collecting and storing blood samples for therapeutic drug monitoring (TDM).

Karppi J, Akerman KK, Parviainen M

Publication: Clin Chem Lab Med (2000) • Vol 38 • Page 313-20PMID: 10928651View on PubMed

Purpose

The purpose of this paper was to determine the effects of collection tube type, delayed centrifugation, and storage of serum in gel barrier tubes on the measurement of therapeutic drugs in serum.

Conclusion

In general, antidepressants and benzodiazepines tended to be adsorbed by the Vacutainer SST, Vacuette gel tubes, and Venoject II gel tubes and recoveries were statistically lower than those measured in their plain counterparts. Recovery of these drugs decreased after storage of serum in the gel barrier tubes at 4 degrees C, for 24 h, after centrifugation. Interestingly, storage of whole blood in gel barrier tubes for 24 h, at 4 degrees C, prior to centrifugation resulted in minimal effects. Antiepileptic, cardioactive, antibiotic, and asthma drug recovery was similar between gel barrier tubes and their plain counterparts.

Studies (1)

Purpose

The purpose of this study was to determine the effects of collection tube type, delayed centrifugation, and storage of serum in gel barrier tubes on the measurement of antiepileptic, antidepressant, psychoactive, cardioactive, and asthma drugs, and antibiotics, valproic acid, carbamazepine, and benzodiazepines in serum. After experimental storage, separated serum was stored at 4 degrees C for up to 1 week unless otherwise indicated. Both spiked and authentic patient specimens were used for these experiments.

Summary of Findings

In general, antidepressants and benzodiazepines tended to be adsorbed by the Vacutainer SST, Vacuette gel tubes, and Venoject II gel tubes and recoveries were statistically lower compared to those measured in their plain counterparts. Recovery of these drugs decreased after storage of serum in the gel barrier tubes at 4 degrees C, for 24 h, after centrifugation. Interestingly, storage of whole blood in gel barrier tubes for 24 h, at 4 degrees C, prior to centrifugation resulted in minimal effects. Antiepileptic, cardioactive, antibiotic, and asthma drug recovery was similar between gel barrier tubes and their plain counterparts. Authentic patient specimens showed higher recovery rates and thus lower adsorption to the barrier gels than spiked specimens, but antidepressant recovery rates were still significantly lower in gel barrier tubes when measured immediately or after 24 h of 4 degrees C storage in the tubes after centrifugation compared to collection and storage in plain tubes.

  • Biospecimens

    FluidSerum
    FluidBlood
  • Preservation Types

    None (Fresh)Other Preservative
  • Diagnoses

    Not specified
  • Platforms

    Small moleculeClinical chemistry/auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionType of collection container/solution
    Vacuette gel tube
    Vacuette plain tube
    Vacutainer SST
    Vacutainer plain tube
    Venoject II gel tube
    Venoject II plain tube
    Biospecimen Aliquots and ComponentsBiospecimen components
    Authentic patient specimen
    Spiked specimen
    Biospecimen Aliquots and ComponentsBlood and blood products
    Serum
    Whole blood
    Biospecimen Aliquots and ComponentsCentrifugation
    Centrifugation delays investigated
    Biospecimen PreservationType of fixation/preservation
    None (fresh)
    Refrigeration
    StorageStorage duration
    0 h
    24 h
    3 h