Skip to main content

Hypothermia and acidosis synergistically impair coagulation in human whole blood.

Dirkmann D, Hanke AA, Görlinger K, Peters J

Publication: Anesth Analg (2008) • Vol 106 • Page 1627-32PMID: 18499589View on PubMed

Purpose

The purpose of this paper was to determine the effects of blood pH and storage temperature on coagulation parameters in sodium citrate whole blood.

Conclusion

Blood analyzed at 30 degrees C had longer coagulation time (CT) and clot formation time (CFT) and lower alpha angle (AA) and maximum clot firmness (MCF) in extrinsic and intrinsic tests than blood analyzed at 36 or 39 degrees C. When blood was analyzed at 36 degrees C, there was no effect of blood pH on the variables, but when blood was analyzed at 33 degrees C, specimens with lower pH tended to have longer CT and CFT and lower AA and MCF than specimens with a pH of 7.37 or those analyzed at 36 or 39 degrees C. Extrinsic and intrinsic clot lysis were decreased in specimens analyzed at 30 degrees C compared to those analyzed at 36 degrees C, and clot lysis was increased in some specimens at 39 degrees C compared to specimens at 33 degrees C, but there were no clear effects of pH on clot lysis.

Studies (1)

Purpose

The purpose of this study was to determine the effects of blood pH and storage temperature on coagulation parameters in sodium citrate-whole blood. Specimens were acidified with hydrochloric acid and incubated at the relevant temperature for 30 min. Specimens were recalcified with calcium chloride.

Summary of Findings

Blood analyzed at 30 degrees C had longer CT and CFT and lower AA and MCF in extrinsic and intrinsic tests than blood analyzed at 36 or 39 degrees C. When blood was analyzed at 36 degrees C, there was no effect of blood pH on the variables, but when blood was analyzed at 33 degrees C, specimens with lower pH tended to have longer CT and CFT and lower AA and MCF than specimens with a pH of 7.37 or those analyzed at 36 or 39 degrees C. In the presence of cytochalasin D, MCF was not influenced by temperature or pH. Extrinsic and intrinsic clot lysis were decreased in specimens analyzed at 30 degrees C compared to those analyzed 36 degrees C, and clot lysis increased in some specimens at 39 degrees C compared to specimens at 33 degrees C, but there were no clear effects of pH on clot lysis.
  • Biospecimens

    FluidBlood
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Normal
  • Platforms

    MorphologyHematology/ auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen Aliquots and ComponentspH
    7
    7.1
    7.2
    7.37
    StorageStorage temperature
    30 degrees C
    33 degrees C
    36 degrees C
    39 degrees C