Skip to main content

Preanalytical variables and off-site blood collection: influences on the results of the prothrombin time/international normalized ratio test and implications for monitoring of oral anticoagulant therapy.

van Geest-Daalderop JH, Mulder AB, Boonman-de Winter LJ, Hoekstra MM, van den Besselaar AM

Publication: Clin Chem (2005) • Vol 51 • Page 561-8PMID: 15650035View on PubMed

Purpose

The purpose of this paper was to determine the effects of delayed centrifugation, centrifugation conditions and storage of plasma after centrifugation on prothrombin time (PT) of plasma.

Conclusion

Generally, delayed centrifugation had effects on PT when blood was stored in Venoject tubes and analyzed with Recombiplastin (center 2), but at center 1, where blood was stored in Monovette or plastic Vacutainer tubes and analyzed using HepatoQuick, delayed centrifugation had inconsistent or no effects on PT. However, at center 1, when specimens were agitated during storage, the magnitude of the changes in PT were generally greater. After centrifugation, storage of plasma for up to 24 h using the conditions of center 2 had no effect on PT, but using center 1's conditions, PT was decreased when plasma was stored for 3 or 6, but not 24 h prior to analysis. There were no significant differences in PT between specimens centrifuged at a controlled temperature of 20 degrees C and those centrifuged without temperature control, and centrifugation time also had no effects on PT.

Studies (1)

Purpose

The purpose of this study was to determine the effects of delayed centrifugation, centrifugation conditions (room temperature or 20°C), centrifugation duration (5 min or 10 min) and storage of plasma after centrifugation on PT in plasma. The study was conducted at 4 different centers, each using different collection tubes types and analysis methods.

Summary of Findings

When tubes of whole blood were stored prior to centrifugation at 4 degrees C, room temperature, or 37 degrees C in center 2 which used Venoject tubes and analyzed with Recombiplastin the PT decreased progressively with storage, except for in tubes stored at 37 degrees C where the PT increased between 3-6 h and 6-24 h. In contrast, when centrifugation was delayed at Center 1 which used Monovette or plastic Vacutainer tubes and analyzed PT using HepatoQuick, no changes were observed in PT of specimens stored at room temperature, but PT increased in specimens stored for 24 h at 4 or 37 degrees C and decreased in specimens stored for 3 h at 37 degrees C. Interestingly, when specimens were stored at room temperature with agitation prior to centrifugation, all specimens, except those from center 2 stored for 3 h, showed significant increases in PT. In specimens from center 3, which used glass Vacutainers and analyzed PT with Symplastin, storage of blood with agitation prior to centrifugation resulted in progressive decreases in PT at 2-4 degrees C, a decrease in PT after 3 h at 37 degrees C, and an increase in PT after 24 h at 37 degrees C. After centrifugation, storage of plasma for up to 24 h prior to analysis using the conditions of center 2 had no effect on PT, but using center 1's conditions, PT was decreased when centrifuged specimens were stored for 3 or 6, but not 24 h prior to analysis. There were no significant differences between the PT of specimens centrifuged at a controlled temperature of 20 degrees C and those centrifuged without temperature control, and centrifugation time also had no effects on PT.

  • Biospecimens

    FluidPlasma
    FluidBlood
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Not specified
  • Platforms

    MorphologyHematology/ auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen Aliquots and ComponentsBlood and blood products
    Plasma
    Whole blood
    Biospecimen Aliquots and ComponentsCentrifugation
    Centrifugation delays investigated
    Multiple durations compared
    Multiple temperatures compared
    StorageStorage conditions
    Mechanical agitation
    No agitation
    StorageStorage duration
    0.5-1 h
    24 h
    3 h
    6 h
    StorageStorage temperature
    37 degrees C
    4-6 degrees C
    Room temperature
    StorageType of storage container
    Glass vacutainer
    Monovette or plastic vacutainer
    Venoject
    Hematology/ auto analyzer SpecificTechnology platform
    HepatoQuick
    Recombiplastin
    Symplastin