RNA quality in fresh frozen prostate tissue from patients operated with radical prostatectomy.

Bertilsson H, Angelsen A, Viset T, Anderssen E, Halgunset J

Publication: Scand J Clin Lab Invest (2010) • Vol 70 • Page 45-53PMID: 20073672View on PubMed

Purpose

The purpose of this paper was to determine the effects of automated RNA extraction on RNA yield and integrity in prostate specimens.

Conclusion

Manual RNA extraction resulted in a higher average yield and RNA integrity number (RIN) than automated RNA extraction. RINs were higher in specimens collected from patients with minimal blood loss during surgery than those who lost significant amounts of blood. RINs were also higher in prostate specimens with little stroma compared to those that were 80% or more stroma.

Studies (1)

Purpose

The purpose of this study was to determine the effects of blood loss during surgery, sampling location, and automated extraction on RNA yield and integrity from frozen prostatectomy specimens. Slices of prostate specimens were taken immediately after surgery and snap-frozen in liquid nitrogen. 5 mm and 3 mm cores were obtained using an electrical drill for automated and manual analysis, respectively. The elution volumes for the 38 automated and 5 manual specimens were 50 and 100 uL, respectively.

Summary of Findings

Manual RNA extraction resulted in a higher average RNA yield (29.5 ng/uL versus 24.2 ng/uL) and RNA integrity number (RIN) (8.7 versus 5.5) than automated RNA extraction. RINs were higher in specimens collected from patients with minimal blood loss during surgery than those who lost significant amounts of blood (p<0.02). RINs were also higher in prostate specimens with little stroma compared to those that were 80% or more stroma (p=0.03). There was a trend toward higher RINs in cores from the specimen center compared to cores from the periphery.
  • Biospecimens

    TissueProstate
  • Preservation Types

    Frozen
  • Diagnoses

    NeoplasticCarcinoma
  • Platforms

    RNASpectrophotometry
    RNAAutomated electrophoresis/Bioanalyzer
    MorphologyH-and-E microscopy
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    PreaquisitionBlood loss amount
    Minor (<1000 mL)
    Significant (>1000 mL)
    Biospecimen Aliquots and ComponentsBiospecimen heterogeneity
    Biospecimen core
    Biospecimen periphery
    Rich in connective tissue
    Rich in epithelial cells
    Analyte Extraction and PurificationAnalyte isolation method
    Automated MagNa Pure method
    Manual HighPure RNA tissue kit