Skip to main content

The use of Vacutainer tubes for collection and storage of blood for coagulation testing.

Thomson JM, Easton AC, Faragher EB

Publication: Clin Lab Haematol (1983) • Vol 5 • Page 413-21PMID: 6667604View on PubMed

Purpose

The purpose of this paper was to determine the effects of storage container, storage temperature and patient condition on coagulation parameters.

Conclusion

Prothrombin time (PT) decreased and factor VII and activated partial thromboplastin time (APTT) increased when blood was stored in vacutainers for 4 h at 4 degrees C, but not when stored in polystyrene tubes at room temperature, compared to measurements taken in unstored specimens. The effects of storage in vacutainers at room temperature or in polystyrene tubes at 4 degrees C were dependent on patient condition.

Studies (1)

Purpose

The purpose of this study was to determine the effects of storage container, storage temperature and patient condition on coagulation parameters. Specimens were first collected through a syringe and distributed into polystyrene tubes containing trisodium citrate, and subsequent specimens were collected directly into vacutainers.

Summary of Findings

For healthy individuals, the PT decreased after 2 to 4 h of storage at 4 degrees C or room temperature in specimens held in vacutainers, but PT was not affected by storage of blood in polystyrene tubes, regardless of storage temperature. Similarly, in patients on coumarin therapy there was a decrease in PT in specimens stored in vacutainers for 4 h at 4 degrees C, but not at room temperature, compared to specimens analyzed after 0 or 2 h or specimens stored in polystyrene tubes. In specimens obtained from women in the third trimester of pregnancy, PT was decreased when blood was stored for 4 h in polystyrene tubes or vacutainers at 4 degrees C but not when specimens were stored at room temperature. When blood from pregnant women was stored at 4 degrees C in vacutainers, Factor VII increased in specimens that were stored for 2 h or more. In specimens from healthy individuals and patients on coumarin therapy, Factor VII increased after 4 h of storage at 4 degrees C. In specimens from healthy individuals and pregnant women, APTT was lengthened in specimens stored at 4 degrees C in vacutainers or polystyrene tubes for 4 h, but APTT was not affected by storage at room temperature or storage of specimens from patients on coumarin therapy.

  • Biospecimens

    FluidBlood
  • Preservation Types

    Frozen
  • Diagnoses

    Normal
    Other diagnoses
    Pregnant
  • Platforms

    MorphologyHematology/ auto analyzer
    ProteinHematology/ auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    PreaquisitionDiagnosis/ patient condition
    Healthy
    Patients on coumarin
    Third-trimester of pregnancy
    StorageStorage duration
    0 h
    2 h
    4 h
    StorageStorage temperature
    4 degrees C
    Room temperature
    StorageType of storage container
    Polystyrene tube with trisodium citrate
    Vacutainer