Impact of analytical bias in metabonomic studies of human blood serum and plasma.

Teahan O, Gamble S, Holmes E, Waxman J, Nicholson JK, Bevan C, Keun HC

Publication: Anal Chem (2006) • Vol 78 • Page 4307-18PMID: 16808437View on PubMed

Purpose

The purpose of this paper was to determine the effects of clotting time and temperature, freeze-thaw cycling, use of plasma instead of serum and delayed analysis on nuclear magnetic resonance (NMR) spectra.

Conclusion

More than 50% of the variation in NMR spectra of serum was attributed to differences between the 4 patients, but small changes attributable to clotting time were observed, and these were partially attenuated when clotting was performed on ice rather than at room temperature. Small differences in spectra were also observed between heparinated plasma and serum specimens, after an additional freeze-thaw cycle or when 1 sample was stored in the NMR machine.

Studies (1)

Purpose

The purpose of this study was to determine the effects of clotting time and temperature, freeze-thaw cycling, use of plasma instead of serum and delayed analysis on NMR spectra. After experimental storage, plasma and serum specimens were stored at -80 degrees C until analysis.

Summary of Findings

More than 50% of the variation in NMR spectra in serum was attributed to differences between the 4 patients. Clotting time increased the peaks associated with lactate, but this was attenuated when clotting was performed on ice rather than at room temperature. Only small differences in spectra were observed between heparinated plasma and serum specimens, and these were predominantly attributed to lipids. Further, small differences in average peak height were observed after serum from 24 individuals was subjected to an additional freeze-thaw cycle, but they were 2 orders of magnitude less than the average peak height and were predominantly due to changes in high molecular weight species. When 1 sample was stored in the NMR machine prior to analysis, a less than 5% variation in spectra was observed over the course of 3 h, but the authors state the variations in lipids that occurred might cause a systematic bias if analysis is delayed.

  • Biospecimens

    FluidPlasma
    FluidSerum
    FluidBlood
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Not specified
  • Platforms

    CarbohydrateNMR
    LipidNMR
    Small moleculeNMR
    SteroidNMR
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen Aliquots and ComponentsBlood and blood products
    Plasma
    Serum
    Biospecimen Aliquots and ComponentsCentrifugation
    Centrifugation delays investigated
    StorageFreeze/thaw cycling
    1 cycle
    2 cycles
    StorageStorage duration
    120 min
    180 min
    30 min
    60 min
    StorageStorage temperature
    On ice
    Room temperature