A comparison of IgG anti-rubella activity in frozen serum stored in primary gel separation tubes or secondary tubes.
Ellis V, Charlett A, Bendall R
Purpose
The purpose of this paper was to determine the effects of storage container on the measurement of anti-rubella immunoglobulin G (IgG) concentrations in serum after 1 year of frozen storage.
Conclusion
After 1 year of storage at -20 degrees C, anti-rubella IgG concentrations were not different between the specimens stored in serum separator tubes (SST) and those stored in plastic microtubes.
Studies (1)
Purpose
The purpose of this study was to determine the effects of storing serum at -20 degrees C for 1 year in primary gel separation tubes as opposed to transferring specimens to new plastic storage tubes on the measurement of anti-rubella IgG concentrations. Specimens were centrifuged and then refrigerated overnight in original collection tubes prior to experimental storage at -20 degrees C, either in same collection tube with new tops, or in a new plastic microtube.
Summary of Findings
After 1 year of storage at -20 degrees C, no differences were found in anti-rubella IgG concentrations between the specimens stored in SST and those stored in plastic microtubes.
Biospecimens
FluidSerumPreservation Types
FrozenDiagnoses
Not specifiedPlatforms
GlycoproteinImmunoassayPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Storage Type of storage container Plastic microtubeVacutainer Plus SST