Skip to main content

A comparison of IgG anti-rubella activity in frozen serum stored in primary gel separation tubes or secondary tubes.

Ellis V, Charlett A, Bendall R

Publication: J Clin Pathol (2004) • Vol 57 • Page 104-6PMID: 14693850View on PubMed

Purpose

The purpose of this paper was to determine the effects of storage container on the measurement of anti-rubella immunoglobulin G (IgG) concentrations in serum after 1 year of frozen storage.

Conclusion

After 1 year of storage at -20 degrees C, anti-rubella IgG concentrations were not different between the specimens stored in serum separator tubes (SST) and those stored in plastic microtubes.

Studies (1)

Purpose

The purpose of this study was to determine the effects of storing serum at -20 degrees C for 1 year in primary gel separation tubes as opposed to transferring specimens to new plastic storage tubes on the measurement of anti-rubella IgG concentrations. Specimens were centrifuged and then refrigerated overnight in original collection tubes prior to experimental storage at -20 degrees C, either in same collection tube with new tops, or in a new plastic microtube.

Summary of Findings

After 1 year of storage at -20 degrees C, no differences were found in anti-rubella IgG concentrations between the specimens stored in SST and those stored in plastic microtubes.
  • Biospecimens

    FluidSerum
  • Preservation Types

    Frozen
  • Diagnoses

    Not specified
  • Platforms

    GlycoproteinImmunoassay
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    StorageType of storage container
    Plastic microtube
    Vacutainer Plus SST