Blood samples drawn from IV catheters have less hemolysis when 5-mL (vs 10-mL) collection tubes are used.
Cox SR, Dages JH, Jarjoura D, Hazelett S
Purpose
The purpose of this paper was to determine the effects of collecting blood in 5 mL versus 10 mL vacuum tubes and the effects of draw order on hemolysis rates.
Conclusion
Use of 10 mL collection tubes resulted in significantly higher rates of hemolysis than 5 mL vacuum tubes as determined by both manual inspection and spectrophotometry, regardless of which tube was filled first.
Studies (1)
Purpose
The purpose of this study was to determine the effects of collecting blood in 5 mL versus 10 mL vacuum tubes and the effects of draw order when drawing blood from intravenous (IV) catheters on hemolysis rates. Each patient had blood collected into two tubes and draw order was randomized.
Summary of Findings
Use of 10 mL collection tubes resulted in significantly higher rates of hemolysis than 5 mL vacuum tubes as determined by both manual inspection and spectrophotometry, regardless of which tube was filled first. The correlation of visual assessment of hemolysis with spectrophotometric determination was 0.74. The authors noted a large rate of variability in hemolysis due to patient and nursing staff methods but did not examine this any further.
Biospecimens
FluidBloodPreservation Types
None (Fresh)Diagnoses
Not specifiedPlatforms
Cell count/volumeMacroscopic observationCell count/volumeSpectrophotometryPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Type of collection container/solution 10 mL vacuum tube5 mL vacuum tubeBiospecimen Aliquots and Components Aliquot sequential collection 1st collection2nd collectionSpectrophotometry Specific Technology platform Macroscopic observation