The purpose of this paper was to determine the effects of collecting central versus peripheral blood on the measurement of Cyclosporine A (CSA) concentrations in pediatric patients treated with CSA.

Conclusion

CSA concentrations were not significantly different between central venous catheter specimens and peripheral specimens (finger prick or venipuncture).

Studies (1)

Purpose

The purpose of this study was to determine the effects of central versus peripheral blood collection on the measurement of CSA concentrations in pediatric patients undergoing stem cell transplants and CSA therapy. The paired specimens were not taken simultaneously, but the time lapse between sampling was recorded (0-50 min, average 16.3 min), and CSA blood concentration was mathematically corrected for sampling time based on the half-life of CSA and dosing schedules.

Summary of Findings

CSA concentrations were not significantly different between central venous catheter specimens and peripheral specimens (finger prick or venipuncture).

  • Biospecimens

    FluidBlood
  • Preservation Types

    None (Fresh)
  • Diagnoses

    NeoplasticLeukemia
    Other diagnoses
  • Platforms

    Small moleculeImmunoassay
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    PreaquisitionDiagnosis/ patient condition
    Hematologic disorder
    Histiocytic disorder
    Inborn error of metabolism
    Primary immunodeficiency
    Biospecimen AcquisitionAnatomical location of blood draw
    Capillary
    Central vein
    Peripheral vein