Skip to main content

Clotting time analysis of citrated blood samples is strongly affected by the tube used for blood sampling.

Ramström S

Publication: Blood Coagul Fibrinolysis (2005) • Vol 16 • Page 447-52PMID: 16093737View on PubMed

Purpose

The purpose of this paper was to determine the effects of collection container, delay to recalcification, and addition of inhibitors of intrinsic or extrinsic clotting pathways on clotting times in recalcified whole blood and platelet-poor plasma (PPP).

Conclusion

The clotting time of whole blood and PPP decreased with storage duration prior to recalcification in specimens collected in Vacutainer or Vacuette tubes. In contrast, whole blood and PPP stored in Monovettes did not show a clear decrease in clotting time with storage prior to recalcification. Whole blood, but not PPP, had longer clotting times in Monovettes than specimens stored in Vacutainers or Vacuettes. Adding corn trypsin inhibitor increased the PPP clotting time, but not whole blood clotting time, for specimens collected in Monovette tubes, but for specimens collected in Vacutainers or Vacuettes, the PPP clotting time increased only when corn trypsin inhibitor was added during sampling. Addition of anti-factor XI antibodies at blood sampling or to PPP increased clotting time for whole blood and PPP, regardless of collection container.

Studies (1)

Purpose

The purpose of this study was to determine the effects of collection container, delay to recalcification, and addition of inhibitors of the intrinsic or extrinsic clotting pathways on clotting times in recalcified whole blood and PPP.

Summary of Findings

The clotting time of whole blood and PPP decreased with storage duration prior to recalcification in specimens collected in Vacutainer or Vacuette tubes with the largest decrease observed after 30 min delays. In contrast, whole blood and PPP stored in Monovettes did not show a clear decrease in clotting time with storage prior to recalcification. Whole blood, but not PPP, had longer clotting times in Monovettes than specimens stored in Vacutainers or Vacuettes. Changing the sodium citrate in the Monovettes from the locally prepared sodium citrate to sodium citrate from Vacutainer tubes did not significantly affect the clotting time of whole blood. Adding corn trypsin increased the PPP clotting time, but not whole blood clotting time, for specimens collected in Monovette tubes, but for specimens collected in Vacutainers or Vacuettes, the PPP clotting time increased only when corn trypsin inhibitor was added during sampling. Addition of anti-factor XI antibodies at blood sampling or to PPP increased clotting time for whole blood and PPP, regardless of collection container. Anti-tissue factor did not have a significant effect on the clotting time.

  • Biospecimens

    FluidBlood
    FluidPlasma
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Normal
  • Platforms

    MorphologyHematology/ auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionAnticoagulant
    Multiple manufacturers evaluated
    Sodium citrate
    Biospecimen AcquisitionType of collection container/solution
    S-Monovette
    Vacuette
    Vacutainer
    Biospecimen Aliquots and ComponentsBiospecimen components
    Anti-factor XI antibodies
    Anti-tissue factor antibodies
    Corn trypsin inhibitor
    None
    Biospecimen Aliquots and ComponentsBlood and blood products
    Platelet-poor plasma
    Whole blood
    StorageTime at room temperature
    1 h
    1.5 h
    15 min
    2 h
    3 h
    30 min