Evaluation of three different specimen types (serum, plasma lithium heparin and serum gel separator) for analysis of certain analytes: clinical significance of differences in results and efficiency in use.
O'Keane MP, Cunningham SK
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine the effects of collection tube type and storage of plasma or serum in the collection tube at room temperature, or as aliquots at 4 degrees C on biochemistry analytes and phenytoin.
Summary of Findings
Potassium levels were higher in serum than plasma and were higher when collected in S than when collected in SST, but all other differences were less than 3% and considered clinically insignificant. When stored at room temperature, potassium, urea and creatinine were most stable when stored in SST and least stable in plasma. In contrast, phenytoin levels decreased significantly after 24 h at room temperature in SST but were stable when stored at room temperature in plasma or S. Carbon dioxide was unstable in plasma or serum stored at room temperature or 4 degrees C, regardless of container. Sodium, chloride, cholesterol, and triglycerides were stable at room temperature for at least 48 h in all containers, and all analytes, except carbon dioxide, were stable for at least 48 h at 4 degrees C.
Biospecimens
FluidSerumFluidPlasmaFluidBloodPreservation Types
None (Fresh)Diagnoses
Not specifiedPlatforms
Electrolyte/MetalIon selective electrodeGasClinical chemistry/auto analyzerSteroidClinical chemistry/auto analyzerSteroidColorimetric assayLipidClinical chemistry/auto analyzerSmall moleculeClinical chemistry/auto analyzerSmall moleculeColorimetric assayPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Type of collection container/solution Lithium heparin vacutainerSerum gel separator tubeSerum vacutainer tubeBiospecimen Aliquots and Components Blood and blood products PlasmaSerumStorage Storage duration 24 h48 h<2 hStorage Storage temperature 4 degrees CRoom temperature