Skip to main content

Postmortem enzyme immunoassay for human immunodeficiency virus.

Klatt EC, Shibata D, Strigle SM

Publication: Arch Pathol Lab Med (1989) • Vol 113 • Page 485-7PMID: 2653271View on PubMed

Purpose

The purpose of this paper was to determine the effects of postmortem interval (PMI) on the detection of human immunodeficiency virus (HIV) in blood and vitreous humor specimens.

Conclusion

HIV was detected in all vitreous humor specimens collected from HIV positive individuals 5-34 h postmortem, and 11 of 16 vitreous humor specimens collected 34-384 h postmortem. HIV was detected in all blood specimens from HIV positive individuals included in this study, even after a postmortem delay of 1392 h. HIV was not detected in blood or vitreous humor collected from HIV negative individuals with PMIs of up to 548 h. In conclusion, HIV was reliably detected in blood and vitreous humor when the PMI was less than 34 h, but after a PMI of more than 34 h blood was more reliable.

Studies (2)

Purpose

The purpose of this study was to determine the effects of PMI on the detection of HIV in blood specimens. Specimens were collected at autopsy and refrigerated at 4 degrees C for 5 h-58 days.

Summary of Findings

HIV was detected in all blood specimens from HIV positive individuals, even after a postmortem delay of 1392 h, and was not detected in blood collected from HIV negative individuals with PMIs of up to 548 h.

  • Biospecimens

    FluidBlood
  • Preservation Types

    Other Preservative
  • Diagnoses

    AIDS/HIV-related
    Autopsy
    Not specified
  • Platforms

    ProteinImmunoassay
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    PreaquisitionPostmortem interval
    10 h
    102 h
    11 h
    120 h
    13 h
    1392 h
    14 h
    144 h
    16 h
    188 h
    20 h
    21 h
    23 h
    24 h
    26 h
    27 h
    31 h
    32 h
    34 h
    36 h
    384 h
    43 h
    432 h
    44 h
    5 h
    51 h
    548 h
    55 h
    60 h
    62 h
    7 h
    72 h
    96 h