A comparison of methods of blood withdrawal and sample preparation for potassium measurements.

Hill AB, Nahrwold ML, Noonan D, Northrop P

Publication: Anesthesiology (1980) • Vol 53 • Page 60-3PMID: 7386910View on PubMed

Purpose

The purpose of this paper was to determine the effects of heparin concentration, sample dilution, draw location, tourniquet application, and delayed analysis on potassium measurement in plasma and serum.

Conclusion

Site of withdrawal, 40 min delays at room temperature prior to analysis (only plasma evaluated), and use of a tourniquet for 3 min had no significant effects on the measurement of potassium levels in plasma or serum. However, increasing heparin concentrations and increasing volumes of diluent decreased potassium levels with serum specimens (no heparin) showing the highest levels of potassium.

Studies (1)

Purpose

The purpose of this study was to determine the effects of heparin concentration, sample dilution, draw location, tourniquet application, and delayed analysis on potassium measurement in plasma and serum.

Summary of Findings

Draw location, 40 min delays at room temperature prior to analysis (only plasma evaluated), and use of a tourniquet for 3 min (rather than no tourniquet) had no significant effects on the measurement of potassium levels in plasma or serum. However, comparing specimens taken from the same site on the basis of presence (plasma) or absence of heparin (serum) revealed that serum specimens with no heparin had higher concentrations of potassium than plasma specimens with heparin. Further, increasing heparin concentrations and increasing volumes of diluent decreased potassium levels.

  • Biospecimens

    FluidPlasma
    FluidSerum
    FluidBlood
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Other diagnoses
  • Platforms

    Electrolyte/MetalClinical chemistry/auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    PreaquisitionDiagnosis/ patient condition
    Patients requiring cardiopulmonary bypass during surgery
    Biospecimen AcquisitionAnatomical location of blood draw
    Artery
    Central vein
    Peripheral vein
    Biospecimen AcquisitionAnticoagulant
    Heparin
    Multiple concentrations evaluated
    None
    Biospecimen AcquisitionCannulation
    16-gauge cannula in peripheral vein
    20-gauge cannula in radial artery
    Swan-Ganz catheter in pulmonary artery via right internal jugular vein
    Biospecimen AcquisitionMethod of fluid acquisition
    Tourniquet times compared
    Biospecimen Aliquots and ComponentsBlood and blood products
    Plasma
    Serum
    StorageTime at room temperature
    40 min
    5 min