Monitoring clozapine: are fingerprick blood and plasma clozapine levels equivalent to arm venipuncture blood and plasma levels?
Goossen RB, Freeman DJ, Satchell AM, Urquhart BL
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine the effects of collection method (fingerprick sampling versus venipuncture), blood component (whole blood versus plasma), and extraction method on the measurement of clozapine levels. This was a pilot study involving 10 patients. For each individual, a fingerprick specimen was collected first and immediately followed by collection of a venipuncture specimen.
Summary of Findings
There were no significant differences in clozapine levels measured in whole blood from fingerprick specimens or venipuncture specimens. Likewise, clozapine levels in plasma were similar between the two specimen types. Solvent extraction yielded similar results to solid phase extraction and allowed for the measurement of clozapine in specimens as small as 50 uL. Clozapine levels in whole blood were approximately 27% lower than those measured in plasma, regardless of collection method or dose of clozapine. The authors note that the differences are not clinically relevant and the same target threshold concentration range can be used, but that the same medium should be used to compare levels in separate specimens.
Biospecimens
FluidBloodFluidPlasmaPreservation Types
None (Fresh)Diagnoses
SchizophreniaPlatforms
Small moleculeHPLCPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Preaquisition Other drugs 175-700 mg/d clozapineBiospecimen Acquisition Anatomical location of blood draw CapillaryVeinBiospecimen Acquisition Method of fluid acquisition Finger/heel prick samplingVenipunctureBiospecimen Aliquots and Components Aliquot size/volume 50 uL500 uLBiospecimen Aliquots and Components Blood and blood products PlasmaWhole bloodAnalyte Extraction and Purification Analyte isolation method Solid phase extractionSolvent extraction