The purpose of this paper was to determine the effects of interfering metabolites, freeze-thaw cycling, anticoagulants, room temperature storage of blood, and measurement method on the determination of total antioxidant capacity (TAC) in plasma.
A new automated method for the determination of the Total Antioxidant Capacity (TAC) of human plasma, based on the crocin bleaching assay.
Kampa M, Nistikaki A, Tsaousis V, Maliaraki N, Notas G, Castanas E
Purpose
Conclusion
The TAC and total antioxidant status (TAS) automated measurement methods showed good linear correlation. After plasma was spiked with various metabolites, it was observed that bilirubin and lipids significantly increased TAC values, ascorbic acid and albumin slightly increased TAC values, and hemoglobin did not interfere with TAC values. Antioxidant capacity of plasma decreased after 3 freeze-thaw cycles and was annihilated after 4 freeze-thaw cycles when measured by the manual colorimetric method. However, plasma TAC values progressively increased after 4 and 5 freeze-thaw cycles when measured by the automated method but were unaffected by up to 3 freeze-thaw cycles. The use of citrated plasma decreased TAC by 20%, and the use of serum (no anticoagulant) increased TAC by 5% compared to both heparinated and EDTA-plasma. Storage of whole blood at room temperature or 4 degrees C for 4 hours prior to centrifugation, and dilution of plasma did not affect TAC values. A diet rich in antioxidants significantly increased TAC values.
Studies (1)
Purpose
The purpose of this study was to determine the effects of endogenous uric acid, other interfering metabolites after plasma was spiked, freeze-thaw cycling, anticoagulants, room temperature storage of blood, and measurement method on the determination of TAC in plasma. Plasma specimens were stored at -80 degrees C prior to analysis.
Summary of Findings
The TAC and TAS automated measurement methods showed good linear correlation (r=0.8478). However, the contribution of endogenous uric acid to TAS assay values was calculated to be 68%, while the contribution of uric acid to TAC assay values was calculated to be 49%. It was also calculated that bilirubin and lipids significantly increased TAC values, ascorbic acid and albumin slightly increased TAC values, and hemoglobin did not interfere with TAC values. Antioxidant capacity of plasma decreased after 3 freeze-thaw cycles and was annihilated after 4 freeze-thaw cycles when measured by the manual colorimetric method. However, plasma TAC values progressively increased after 4 and 5 freeze-thaw cycles when measured by the automated method and were unaffected by up to 3 freeze-thaw cycles. The use of citrated plasma decreased TAC by 20%, and the use of serum (no anticoagulant) increased TAC by 5% compared to both heparinated and K3EDTA-plasma, which showed results that were similar to one another. The effect of anticoagulant was present after 0 or 4 h of storage of whole blood at room temperature or 4 degrees C prior to centrifugation. Dilution of plasma did not significantly affect TAC values. TAC values measured in specimens taken from individuals following a diet rich in antioxidants (vegan with large amounts of fruits, vegetables, and extra virgin olive oil) showed a broader distribution and a mean value that was about twice that measured in plasma from individuals following a normal diet (p<0.0001).
Biospecimens
FluidPlasmaFluidSerumFluidBloodPreservation Types
FrozenDiagnoses
NormalPlatforms
LipidClinical chemistry/auto analyzerLipidColorimetric assayProteinClinical chemistry/auto analyzerProteinColorimetric assaySmall moleculeClinical chemistry/auto analyzerSmall moleculeColorimetric assayElectrolyte/MetalClinical chemistry/auto analyzerElectrolyte/MetalColorimetric assayPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Preaquisition Patient diet Normal dietVegan diet rich in fruit, vegetables, and olive oilBiospecimen Acquisition Anticoagulant CitrateHeparinNonePotassium EDTABiospecimen Aliquots and Components Aliquot size/volume Plasma dilution factor 1-8Biospecimen Aliquots and Components Biospecimen components PlasmaPlasma spiked with albuminPlasma spiked with ascorbatePlasma spiked with bilirubinPlasma spiked with conjugated bilirubinPlasma spiked with hemoglobinPlasma spiked with lipidsBiospecimen Aliquots and Components Blood and blood products PlasmaSerumBiospecimen Aliquots and Components Centrifugation Centrifugation delays investigatedStorage Freeze/thaw cycling 1 cycle2 cycles3 cycles4 cycles5 cyclesStorage Storage duration 0 h4 hStorage Storage temperature 4 degrees CRoom temperatureClinical chemistry/auto analyzer Specific Technology platform Manual assayTAC assayTAS assay