Skip to main content

Biological qualification of blood units: considerations about the effects of sample's handling and storage on stability of nucleic acids.

Gessoni G, Barin P, Valverde S, Giacomini A, Di Natale C, Orlandini E, Arreghini N, De Fusco G, Frigato A, Fezzi M, Antico F, Marchiori G

Publication: Transfus Apher Sci (2004) • Vol 30 • Page 197-203PMID: 15172624View on PubMed

Purpose

The purpose of this paper was to determine the effects of delayed centrifugation and of 5 freeze-thaw cycles on plasma hepatitis B virus (HBV), hepatitis C virus (HCV), and human immunodeficiency virus (HIV) loads.

Conclusion

After 168 h of storage of EDTA-blood at 4 degrees C or 5 freeze-thaw cycles, the average HBV, HCV and HIV viral loads in plasma declined compared to those found in plasma obtained from immediately centrifuged blood and plasma that was thawed only once.

Studies (1)

Purpose

The purpose of this study was to determine the effects of delayed centrifugation and of 5 freeze-thaw cycles on plasma HBV, HCV, and HIV viral loads. The first 3 h of experimental storage were at room temperature, and the remainder was at 4 degrees C. After experimental storage, the plasma fractions were stored at -80 degrees C. Specimens were thawed in a 37 degrees C water bath.

Summary of Findings

After 168 h of storage of EDTA-blood at 4 degrees C, the average HBV, HCV and HIV viral loads in plasma declined by 0.148, 0.477, and 0.336 log, respectively, compared to plasma that was immediately separated and frozen. Importantly, the number of specimens showing a more than 0.3 log decline after delayed centrifugation was 1/25, 110/110, and 4/25 for HBV, HCV, and HIV, respectively. After 5 freeze-thaw cycles, the plasma HBV, HCV, and HIV loads declined by an average of 0.174, 0.871, and 0.623 log, respectively, compared to specimens thawed once. While the viral load in only 1/25 HBV positive specimens declined by more than 0.3 log, all 110 HCV and 25 HIV specimens showed a decline of more than 0.3 log after 5 freeze-thaw cycles compared to after 1 freeze-thaw cycle.

  • Biospecimens

    FluidBlood
    FluidPlasma
  • Preservation Types

    Frozen
  • Diagnoses

    AIDS/HIV-related
    Hepatitis
  • Platforms

    RNANucleic acid sequence-based amplification (NASBA)
    RNART-PCR
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen Aliquots and ComponentsCentrifugation
    Centrifugation delays investigated
    StorageFreeze/thaw cycling
    1 cycle
    5 cycles
    StorageStorage duration
    0 h
    168 h
    24 h
    48 h
    72 h