Further evaluation of a new standard of efficacy for stored platelets.
AuBuchon JP, Herschel L, Roger J
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine the effects of collection method, storage and radiolabel on platelet recovery and survival.
Summary of Findings
Platelets obtained using an apheresis unit that were retransfused on day 1 of storage had a 65.1% recovery rate with an average survival of 7.7 days. After 7 days of storage of platelets at 20-24 degrees C, the mean platelet recovery rate was 56.4%, and the mean survival decreased by 15.7% to 6.5 days. In a second study, manually separated and retransfused platelets showed a mean recovery rate of 59.5% after 1 day and 50.4% after 7 days. Further, the mean survival rate decreased from 8.8 days in platelets retransfused on day 1 to 6.7 days in platelets stored for 7 days. Generally, manual separation was associated with lower platelet recovery, but longer survival compared to apheresis. When platelets were radiolabelled with In111 or Cr51 and retransfused, there were no differences in mean recovery or survival rates between the two radiolabels.
Biospecimens
FluidBloodPreservation Types
None (Fresh)Diagnoses
NormalPlatforms
Cell count/volumeRadioassayPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Method of fluid acquisition ApheresisVenipunctureBiospecimen Aliquots and Components Blood processing method ApheresisManual separationStorage Storage duration 7 days< 1 dayRadioassay Specific Detection method Cr51In111