Skip to main content

Stability of ribavirin concentrations depending on the type of blood collection tube and preanalytical conditions.

Marquet P, Sauvage FL, Loustaud-Ratti V, Babany G, Rousseau A, Lachâtre G

Publication: Ther Drug Monit (2010) • Vol 32 • Page 237-41PMID: 20216114View on PubMedSuggested by: ISBER

Purpose

The purpose of this paper was to determine the effects of collection tube type and storage prior to and after centrifugation on measurement of ribavirin in plasma and serum.

Conclusion

No significant differences were observed between ribavirin concentrations measured in serum, EDTA-plasma, and lithium heparinated-plasma. In collection tubes without gel separators, delayed centrifugation tended to decrease ribavirin concentration in plasma and increase ribavirin concentration in serum. Holding specimens on ice rather than at 4 degrees C or room temperature attenuated these effects. The use of serum separator tubes (SST II) or lithium heparin plasma separator tubes (LH PST II) tended to stabilize ribavirin concentrations during a post-centrifugation delay at room temperature prior to transferring serum or plasma to new tubes. However, 2 h pre-centrifugation delays resulted in decreased ribavirin concentrations in plasma collected in LH PST II tubes, and larger decreases were seen when the specimens were held for 2 h at ambient temperatures compared to 4 degrees C.

Studies (1)

Purpose

The purpose of this study was to determine the effects of anticoagulant, collection tube type, delayed centrifugation, storage temperature, and delayed removal of serum and plasma specimens from the collection tubes after centrifugation on measured ribavirin concentrations. After specimens were subjected to various temperature/storage conditions, they were transferred to Eppendorf tubes and frozen at -20 degrees C until analysis within 1 week.

Summary of Findings

When collection tubes without gel separators were used, no significant differences were observed between ribavirin concentrations measured in serum, EDTA-plasma, and lithium heparinated-plasma. Ribavirin concentrations in plasma showed small decreases when centrifugation was delayed. The specimens held on ice prior to centrifugation showed smaller declines in ribavirin concentration than those held at 4 degrees C or room temperature. Ribavirin concentrations in serum showed insignificant increases when centrifugation was delayed, and storage on ice attenuated these changes. The use of gel tubes (SST II or LH PST II) resulted in very little change in ribavirin concentrations when tubes were held at room temperature for 2 h post-centrifugation, prior to transferring serum or plasma to new tubes. Extending this post-centrifugation delay to 24 h did not affect ribavirin concentrations in gel tubes, but decreased plasma ribavirin concentrations were observed when EDTA tubes were held on ice for 24 h prior to centrifugation rather than assayed immediately. However, the authors note the sample size for the 24 h experiments (centrifuged gel tubes versus uncentrifuged EDTA tubes) was only 3. Delaying centrifugation by 2 h resulted in decreased ribavirin concentrations in plasma collected in lithium heparin PST II tubes. Larger decreases in ribavirin concentrations were seen when the specimens were held for 2 h at ambient temperatures compared to 4 degrees C, but storage duration in the original collection tube after centrifugation had no significant effect.

  • Biospecimens

    FluidPlasma
    FluidSerum
    FluidBlood
  • Preservation Types

    Frozen
  • Diagnoses

    Hepatitis
  • Platforms

    Small moleculeLC-MS or LC-MS/MS
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    PreaquisitionOther drugs
    Peginterferon
    Ribavirin
    Biospecimen AcquisitionAnticoagulant
    EDTA
    Gel-barrier
    Lithium heparin
    None
    Biospecimen AcquisitionType of collection container/solution
    Plain tube
    Serum separator tube (SST)
    Biospecimen Aliquots and ComponentsBlood and blood products
    Plasma
    Serum
    Biospecimen Aliquots and ComponentsCentrifugation
    Centrifugation delays investigated
    StorageStorage conditions
    Post-centrifugation in original collection tube
    Prior to centrifugation
    StorageStorage duration
    0 min
    2 h
    24 h
    30 min
    StorageStorage temperature
    25 degrees C
    4 degrees C
    On ice