The purpose of this paper was to determine the effects of thawing method and time post-thaw on clotting factors activity in plasma.
Thawing procedures and the time course of clotting factor activity in fresh-frozen plasma: a controlled laboratory investigation.
von Heymann C, Pruss A, Sander M, Finkeldey A, Ziemer S, Kalus U, Kiesewetter H, Salama A, Spies C
Purpose
Conclusion
Thaw methods and temperatures (35, 37, or 42 degrees C) did not significantly affect the measurement of any analytes. Factor VII levels decreased significantly and fibrin monomers increased after 1 freeze-thaw cycle compared to levels measured at blood sampling. Levels of analytes were not significantly different up to 6 h after thaw compared to levels measured within 1 hour of thawing.
Studies (1)
Purpose
The purpose of this study was to determine the effects of thawing method and time post-thaw on clotting factor activity in plasma. A baseline measurement was taken prior to storage of the plasma at -30 to -40 degrees C for 8 weeks and specimen thawing.
Summary of Findings
Although the three methods of thawing and thaw temperatures (35, 37, or 42 degrees C) required significantly different thaw times, thaw method did not significantly affect the measurement of any analytes. With the exception of Factor VII, levels of all analytes were within the normal range. Factor VII levels decreased significantly, and fibrin monomers increased after 1 freeze-thaw cycle compared to levels measured at blood sampling (p<0.01 and p=0.001, respectively). Levels of analytes were not significantly different up to 6 h after thaw compared to levels measured within 1 hour of thawing.
Biospecimens
FluidPlasmaPreservation Types
FrozenNone (Fresh)Diagnoses
NormalPlatforms
ProteinClinical chemistry/auto analyzerSmall moleculeImmunoassayMorphologyHematology/ auto analyzerGlycoproteinClinical chemistry/auto analyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Preservation Type of fixation/preservation FrozenNone (fresh)Storage Post-thaw duration 1 h2 h4 h6 hStorage Thaw temperature/condition 37 degrees C shaking water bath42 degrees C running waterMicrowave with maximum temperature of 35 degrees C