Skip to main content

Influence of pre-analytical and analytical factors on soluble CD40L measurements.

Varo N, Nuzzo R, Natal C, Libby P, Schönbeck U

Publication: Clin Sci (Lond) (2006) • Vol 111 • Page 341-7PMID: 16856875View on PubMedSuggested by: ISBER

Purpose

The purpose of this paper was to determine the effects of specimen type, anticoagulant choice, delay to centrifugation, centrifugation speed, storage, freeze-thaw cycling, and blood components on the measurement of soluble CD40 ligand (sCD40L).

Conclusion

sCD40L levels were higher in serum than in plasma, but were unaffected by the type of anticoagulant used. Levels of sCD40L increased in serum when blood was stored at room temperature for 2 h or 6 h prior to centrifugation rather than for 30 min. Increasing the centrifugation speed led to a gradual decrease in sCD40L levels measured in plasma as the platelet and leukocyte levels decreased. Up to 3 freeze-thaw cycles did not affect sCD40L levels in plasma with a low platelet count but increased sCD40L in platelet rich plasma. After centrifugation, storage of serum at 4 degrees C for 48 h did not affect sCD40L levels, but when serum was stored at room temperature, sCD40L levels declined with storage. Bilirubin and hemoglobin interfered with the measurement of sCD40L at all levels, but cholesterol and triglycerides only affected sCD40L measurement when present at pathological levels. Endogenous sCD40L was not detected in urine specimens, but recovery of spiked sCD40L was highest in urine specimens with a pH of 5-8.

Studies (2)

Purpose

The purpose of this study was to determine the effects of anticoagulant choice, delay to centrifugation, centrifugation speed (200 x g, 400 x g, 1000 x g, 2000 x g, 13000 x g), storage, freeze-thaw cycling, and blood components on the measurement of sCD40L.

Summary of Findings

sCD40L levels were higher in serum than in plasma (p=0.001) and were not correlated with one another. There were no significant differences in sCD40L levels when heparin, EDTA, or citrate was used for anticoagulation. When blood was stored at room temperature for 2 h or 6 h prior to centrifugation, levels of sCD40L in serum were 15 and 22% higher, respectively than when blood was stored for 30 min. Increasing the centrifugation speed led to a gradual decrease in sCD40L levels measured in plasma as the platelet and leukocyte levels decreased, but no additional effect was noted at centrifugation speeds greater than 1000 g. Up to 3 freeze-thaw cycles did not affect sCD40L levels in plasma with a low platelet count but increased sCD40L in platelet rich plasma. After centrifugation, storage of serum at 4 degrees C for 48 h did not affect sCD40L levels, but when serum was stored at room temperature, sCD40L levels declined with storage. Bilirubin and hemoglobin interfered with the measurement of sCD40L at all levels. While normal physiological concentrations of cholesterol and triglycerides (<250 mg/dL and <200 mg/dL respectively) did not affect measurement of sCD40L, pathological levels of triglycerides and cholesterol led to decreases in measured sCD40L levels. sCD40L levels were higher in plasma from diabetic patients than healthy controls.

  • Biospecimens

    FluidPlasma
    FluidSerum
    FluidBlood
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Diabetes Type 2
    Diabetes Type 1
    Normal
  • Platforms

    ProteinELISA
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    PreaquisitionBiomarker level
    Bilirubin (50-200 mg/mL)
    Cholesterol (150-300 mg/dL)
    Hemoglobin (12-36 mg/mL)
    High sCD40L
    Low sCD40L
    Triglycerides (50-400 mg/dL)
    PreaquisitionDiagnosis/ patient condition
    Diabetes
    Normal
    Biospecimen AcquisitionAnticoagulant
    Citrate
    EDTA
    Heparin
    None
    Biospecimen Aliquots and ComponentsBlood and blood products
    Platelet-poor plasma
    Platelet-rich plasma
    Serum
    Biospecimen Aliquots and ComponentsCentrifugation
    Centrifugation delays investigated
    Multiple speeds compared
    StorageFreeze/thaw cycling
    0 cycles
    1 cycle
    2 cycles
    3 cycles
    StorageStorage duration
    0 h
    24 h
    48 h
    6 h
    StorageStorage temperature
    4 degrees C
    Room temperature
    StorageTime at room temperature
    2 h
    30 min
    6 h