Measurement of urinary cystatin C by particle-enhanced nephelometric immunoassay: precision, interferences, stability and reference range.

Herget-Rosenthal S, Feldkamp T, Volbracht L, Kribben A

Publication: Ann Clin Biochem (2004) • Vol 41 • Page 111-8PMID: 15025800View on PubMedSuggested by: ISBER

Purpose

The purpose of this paper was to determine the effects of storage, freeze-thaw cycling, pH, and urine components on cystatin C levels in urine.

Conclusion

Urine cystatin C concentrations remained stable for up to 7 days at -20 degrees C or 4 degrees C, 48 h at 20 degrees C, and through three freeze-thaw cycles. Cystatin C concentrations were stable in urine with a pH of 5-9, but when the pH was adjusted to 4.0 or 3.0, cystatin C decreased. Cystatin C was not adsorbed in the polyvinyl chloride collection bags, and albumin, bilirubin and haemoglobin in the urine did not interfere with measurement of cystatin C.

Studies (1)

Purpose

The purpose of this study was to determine the effects of storage, freeze-thaw cycling, pH, and urine components on cystatin C levels in urine.

Summary of Findings

Urine cystatin C concentrations remained stable for up to 7 days at -20 degrees C or 4 degrees C, or 48 h at 20 degrees C, but after 28 days at -20 degrees C, urinary cystatin C decreased by 30.8% (p<0.01). After 72 h at 20 degrees C, urinary cystatin C decreased by 8.8% (p<0.05). Three freeze-thaw cycles had no effect on cystatin C concentrations compared to those measured in fresh specimens. Cystatin C concentrations were stable in urine with a pH of 5-9, but when the pH was adjusted to 4.0 or 3.0, cystatin C decreased by 26.6% and 85.3%, respectively. When the pH was brought back to 5 from 4, after 6 h at 4 degrees C, cystatin C levels returned to normal, but after longer storage at 4 degrees C or -20 degrees C, readjustment of the pH did not return cystatin C levels to normal. Bringing the pH back to 5 from 3 did not bring the cystatin C levels back to normal. Cystatin C was not adsorbed in the polyvinyl chloride collection bags, and albumin, bilirubin and haemoglobin in the urine did not interfere with measurement of cystatin C levels in urine.
  • Biospecimens

    FluidUrine
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Normal
    Other diagnoses
  • Platforms

    ProteinClinical chemistry/auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    PreaquisitionBiomarker level
    15-210 umol/L haemoglobin
    25-500 umol/L bilirubin
    60-160 g/L albumin
    PreaquisitionDiagnosis/ patient condition
    Acute tubular necrosis
    Renal failure
    Biospecimen Aliquots and ComponentspH
    10
    3
    4
    5
    6
    7
    8
    9
    StorageFreeze/thaw cycling
    0 cycles
    1 cycle
    2 cycles
    3 cycles
    StorageStorage duration
    0 h
    24 h
    28 days
    48 h
    6 h
    7 days
    72 h
    StorageStorage temperature
    -20 degrees C
    20 degrees C
    4 degrees C
    StorageType of storage container
    None
    Polyvinyl chloride urine collection bag