The purpose of this paper was to determine the effects of thawing method and storage at 4 degrees C on factor V (FV), factor VIII (FVIII) and protein S (PS) levels in plasma.
Rapid thawing of fresh-frozen plasma with radio wave-based thawing technology and effects on coagulation factors during prolonged storage at 4 degrees C.
Boström F, Ekemar L, Olsson D, Egberg N, Lundahl J
Purpose
Conclusion
When plasma was thawed using a radio wave thawing device (RTD), the temperature after thaw was higher than when plasma was thawed by heated air technology (HAT), but there were no differences in the levels of FV, FVIII and PS when the two thawing methods were compared. After thawing, FV and FVIII levels were more than 90% of the prefreezing values, but after 2 weeks of storage at 4 degrees C and a second freeze-thaw cycle, levels decreased to 70% and 40% of the prefreezing values, respectively. PS levels declined by approximately 10% after a 2 weeks thaw duration and a second freeze-thaw cycle.
Studies (1)
Purpose
Summary of Findings
Biospecimens
FluidPlasmaPreservation Types
FrozenDiagnoses
Not specifiedPlatforms
ProteinHematology/ auto analyzerProteinImmunoassayPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Storage Freeze/thaw cycling 1 cycle2 cyclesStorage Thaw duration 1 week2 weeksLess than 20 min