Antigen retrieval techniques in immunohistochemistry: comparison of different methods.
Pileri SA, Roncador G, Ceccarelli C, Piccioli M, Briskomatis A, Sabattini E, Ascani S, Santini D, Piccaluga PP, Leone O, Damiani S, Ercolessi C, Sandri F, Pieri F, Leoncini L, Falini B
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine the effects of AR technique, type of fixative, duration of fixation, and IHC detection method on IHC staining in a variety of normal and pathological tissues including acute non-lymphoid leukaemia and intermediate cell neuroendocrine carcinoma. A panel of 61 antibodies was used for IHC staining of tissue.
Summary of Findings
Detection of IHC staining using automated or manual APAAP methods was comparable to detection using a modified streptavidin-biotin complex immunoperoxidase method. Although antigen specific effects were noted, in general, HIAR yielded immunostaining results that were superior to the use of protease XIV, including less background staining, staining of otherwise undetectable antigens, and allowing for the use of a higher antibody working dilution. HIAR was equally as effective in formalin- and B5-fixed specimens and attenuated differences in staining seen between specimens fixed in formalin for 24 h and 1 week. After AR by protease XIV, IHC staining was particularly unpredictable in B5-fixed specimens compared to formalin-fixed specimens where 5 antibodies benefitted from proteolytic enzyme treatment. Generally speaking, for antigens where AR was not necessary to obtain adequate immunostaining, a lower working dilution of antibody was necessary compared to the working dilution used after AR. HIAR yielded superior IHC results when EDTA buffer was used compared to Tris-HCl and citrate buffer, the latter faring the worst. Notably, EDTA buffer was superior regardless of fixative (formalin versus B5), nature of the antibodies (monoclonal versus polyclonal), or source of heat (microwave versus pressure cooker). While no significant differences were noted between HIAR by microwave irradiation as opposed to pressure cooking, pressure cooking for 90 seconds was superior to 1 or 2 minutes.
Biospecimens
TissueBone MarrowTissuePlacentaTissueLymph NodeTissueBreastTissueColorectalTissueStomachTissueProstateTissueEndometriumTissueThyroid GlandTissueLarynxTissueEyeTissueMuscle (Skeletal)TissueOtherTissueBrainPreservation Types
FormalinOther PreservativeDiagnoses
NormalNeoplasticCarcinomaNeoplasticLymphomaNeoplasticSarcomaNeoplasticLeukemiaPlatforms
ProteinImmunohistochemistryPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Aliquots and Components Type of slide Naturally chargedSilane-coatedBiospecimen Preservation Time in fixative 2 h-2 h 30 min (B5)24 h-1 week (formalin)Biospecimen Preservation Type of fixation/preservation B-5 fixativeFormalin (buffered)Analyte Extraction and Purification Antigen retrieval HIAR in EDTA-NaOHHIAR in Tris-HCl bufferHIAR in citrate bufferNoneProtease digestionAnalyte Extraction and Purification Temperature of heat-induced retrieval MicrowavePressure cooker 1 minPressure cooker 2 minPressure cooker 90 secImmunohistochemistry Specific Antibody dilution/concentration A broad range was investigatedImmunohistochemistry Specific Detection method Automated APAAPManual APAAPModified streptavidin-biotin complex immunoperoxidase