Influence of tissue preparation on the high-frequency acoustic properties of normal kidney tissue.

Sasaki H, Saijo Y, Tanaka M, Okawai H, Terasawa Y, Yambe T, Nitta S

Publication: Ultrasound Med Biol (1996) • Vol 22 • Page 1261-5PMID: 9123651View on PubMed

Purpose

The purpose of this paper was to determine the effects of preservation method on the acoustic properties of normal kidney tissue.

Conclusion

The renal corpuscle and renal tubules were not distinguishable in frozen sections of unfixed kidney tissue, while they were in formalin-fixed paraffin-embedded (FFPE) and formalin-fixed frozen (FFF) preparations. The attenuation constants and sound speeds of the whole renal cortex or the renal medulla were not significantly different between preparation methods.

Studies (1)

Purpose

The purpose of this study was to compare the retention of acoustic properties in frozen, FFPE, and FFF normal kidney specimens. The latter preparation method consisted of formalin fixation and subsequent freezing of tissue in acetone instead of embedding it in paraffin.

Summary of Findings

The renal corpuscle and renal tubules were not distinguishable in frozen sections of unfixed kidney tissue, while they were in FFPE and FFF preparations. The attenuation constants and sound speeds of the whole renal cortex or the renal medulla were not significantly different between preparation methods.

  • Biospecimens

    TissueKidney
  • Preservation Types

    FormalinFrozen
  • Diagnoses

    Normal
  • Platforms

    MorphologyScanning acoustic microscopy
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen Aliquots and ComponentsBiospecimen components
    Renal corpuscle
    Renal cortex
    Renal medulla
    Renal tubule
    Biospecimen PreservationEmbedding medium
    Conventional paraffin embedding
    Not embedded
    Biospecimen PreservationType of fixation/preservation
    Formalin (buffered)
    Frozen