Method of specimen fixation and pathological dissection of colorectal cancer influences retrieval of lymph nodes and tumour nodal stage.
Poller DN
Purpose
The purpose of this paper was to determine the effects of removal of the mesocolonic or mesorectal fat and an additional 24 h of fixation after fat removal on the determination of lymph node positive/negative status in colorectal cancer specimens.
Conclusion
Dissection of the mesocolonic or mesorectal fat from colcorectal carcinoma specimens and an additional 24 h of fixation led to the identification of significantly more specimens with lymph node involvement than when no dissection or additional fixation was performed.
Studies (1)
Purpose
The purpose of this study was to determine the effects of removal of the mesocolonic or mesorectal fat and an additional 24 h of fixation after its removal on the determination of lymph node positive/negative status in colorectal cancer specimens.
Summary of Findings
The author states that with an additional 24 h fixation after the removal of mesocolonic or mesorectal fat, lymph nodes adjacent to tumor tissue were more easily palpated and thus more easily identified. This dissection and additional fixation led to the identification of significantly more specimens with lymph node involvement than when no dissection or additional fixation was performed (p=0.028). While the average number of total lymph nodes identified in the dissected and additionally fixed specimens was not significantly different from the control group, the number of specimens where a single positive tumor-containing lymph node was identified was significantly higher in the dissected and additionally fixed group than in the control group (p=0.0025).