The stability of the circulating human proteome to variations in sample collection and handling procedures measured with an aptamer-based proteomics array.

Ostroff R, Foreman T, Keeney TR, Stratford S, Walker JJ, Zichi D

Publication: J Proteomics (2010) • Vol 73 • Page 649-66PMID: 19755178View on PubMed

Purpose

The purpose of this paper was to determine the effects of collection tube type, delayed centrifugation, and delayed freezing on protein concentrations in serum and plasma.

Conclusion

Of 498 proteins investigated, 83% were stable, regardless of collection tube type, time between blood collection and centrifugation, time between centrifugation and freezing, or analysis of plasma or serum. In plasma, 90% of proteins were stable across all storage conditions. In Red Top (no additive) and SST serum specimens, 86% and 73% of proteins were stable across all storage conditions. Nearly all of the instability in serum or plasma specimens occurred when specimens were stored for more than 2 h at room temperature either before centrifugation or between centrifugation and freezing.

Studies (1)

Purpose

The purpose of this study was to determine the effects of collection tube type, delayed centrifugation, and delayed freezing on protein concentrations measured by an aptamer-based proteomics array in serum and plasma. Specimens were stored for various durations at room temperature either before centrifugation or between centrifugation and freezing. For the 20 h duration, however, storage prior to centrifugation was for 4 h at room temperature followed by 16 h at 4 degrees C, and storage between centrifugation and freezing was for 6 h at room temperature followed by 14 h at 4 degrees C.

Summary of Findings

Of 498 proteins investigated, 83% were stable, regardless of collection tube type, storage for 30 min-20 h between blood collection and centrifugation or between centrifugation and freezing, or analysis of plasma or serum. In plasma, 90% of proteins were stable across all storage conditions. In Red Top (no additive) and SST serum specimens, 86% and 73% of proteins were stable across all storage conditions. Nearly all of the instability in serum or plasma specimens resulted when specimens were stored at room temperature for more than 2 h either before centrifugation or between centrifugation and freezing.

  • Biospecimens

    FluidPlasma
    FluidSerum
    FluidBlood
  • Preservation Types

    Frozen
  • Diagnoses

    Not specified
  • Platforms

    ProteinAptamer-based microarray
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionType of collection container/solution
    PPT EDTA plasma tube
    Red Top serum tube
    SST serum separator tube
    Biospecimen Aliquots and ComponentsBlood and blood products
    Plasma
    Serum
    Biospecimen Aliquots and ComponentsCentrifugation
    Centrifugation delays investigated
    StorageTime at room temperature
    1 h
    2 h
    20 h
    30 min
    6 h