Immunohistochemical detection of immunoglobulin light chain expression in B-cell non-Hodgkin lymphomas using formalin-fixed, paraffin-embedded tissues and a heat-induced epitope retrieval technique.

Marshall-Taylor CE, Cartun RW, Mandich D, DiGiuseppe JA

Publication: Appl Immunohistochem Mol Morphol (2002) • Vol 10 • Page 258-62PMID: 12373154View on PubMed

Purpose

The purpose of this paper was to compare diagnoses of B-cell non-Hodgkin lymphomas (NHL) by immunoglobulin light chain immunohistochemical (IHC) staining of formalin-fixed paraffin-embedded (FFPE) specimens with heat-induced antigen retrieval with that by flow cytometric immunophenotyping.

Conclusion

With flow cytometric immunophenotyping taken as the standard, IHC of 73 FFPE specimens resulted in 100% specificity for being diagnostic of either kappa or lambda light chain restriction. IHC sensitivities for kappa and lambda restriction were 83% and 81%, respectively and were not significantly different from one another. Further, detection of light chain restriction among different types of NHL was not significantly different. High interobserver concordance was observed for IHC (87%). Importantly, 5 of 8 cases that were indeterminate by flow cytometry demonstrated light chain restriction by IHC. The authors emphasize the ability to complete the IHC analysis using only small amounts of core biopsy tissue, and that tissue loss was minimized with their specific antigen retrieval method.

Studies (1)

Purpose

The purpose of this study was to compare diagnoses of B-cell NHL by immunoglobulin light chain IHC staining of FFPE specimens with heat-induced antigen retrieval with flow cytometric immunophenotyping. Antigen retrieval was accomplished by heating specimens to 96 degrees C in Target Retrieval Solution (DAKO) for 40 min in a water bath.

Summary of Findings

With flow cytometric immunophenotyping taken as the standard, IHC of 73 FFPE specimens resulted in 100% specificity for being diagnostic of either kappa or lambda light chain restriction. IHC sensitivities for kappa and lambda restriction were 83% and 81%, respectively and were not significantly different from one another. Further, detection of light chain restriction among different types of NHL was not significantly different. High interobserver concordance was observed for IHC (87%). Importantly, 5 of 8 cases that were indeterminate by flow cytometry demonstrated light chain restriction by IHC. The authors emphasize the ability to complete the IHC analysis using only small amounts of core biopsy tissue, and that tissue loss was minimized with their specific antigen retrieval method.
  • Biospecimens

    TissueLymph Node
  • Preservation Types

    Formalin
  • Diagnoses

    NeoplasticLymphoma
  • Platforms

    ProteinImmunohistochemistry
    ProteinFlow cytometry
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    PreaquisitionDiagnosis/ patient condition
    12 types of non-Hodgkin lymphomas
    Immunohistochemistry SpecificTargeted peptide/protein
    Kappa light chain
    Lambda light chain
    Immunohistochemistry SpecificTechnology platform
    Flow cytometry
    Flow cytometry SpecificTargeted peptide/protein
    Kappa light chain
    Lambda light chain