Immunoguided laser assisted microdissection techniques for DNA methylation analysis of archival tissue specimens.
Eberle FC, Hanson JC, Killian JK, Wei L, Ylaya K, Hewitt SM, Jaffe ES, Emmert-Buck MR, Rodriguez-Canales J
Purpose
The purpose of this paper was to develop protocols for antigen retrieval and immunohistochemistry (IHC) compatible with immunoguided laser-assisted microdissection (ILAM) of formalin-fixed paraffin-embedded (FFPE) specimens and to determine its effects on DNA methylation.
Conclusion
When antigen retrieval was performed with pepsin or heat-induced antigen retrieval (HIER) at 60 degrees C, none of the tissue sections were lost, but the authors report that pepsin applied on a horizontal surface at 37 degrees C for 10 min led to the best results. When 75,000 tumor cells were obtained by ILAM, rather than hematoxylin and eosin (H&E) guided laser assisted microdissection (LAM), 9-64% as much DNA was obtained. Amplification of 152 bp and 268 bp fragments of beta-globin was similarly successful in LAM and ILAM cells, and amplification of a 676 bp fragment of beta-globin was not possible with DNA obtained from ILAM or LAM cells. CpG methylation was strongly correlated between the ILAM and LAM cells.
Studies (2)
Purpose
The purpose of this study was to determine the effects of slide pretreatment, slide type, antigen retrieval method, and IHC protocol on specimen loss and IHC staining of lymphomas.
Summary of Findings
When slides were not pretreated, the tissue sections were lost during antigen retrieval, but the problem was eliminated by ultraviolet (UV) irradiation and poly-L-lysine coating of the slides prior to tissue mounting and incubation of the slides at 60 degrees C after tissue mounting. When antigen retrieval was performed with pepsin or HIER at 60 degrees C, none of the tissue sections were lost, but the authors report that pepsin applied on a horizontal surface at 37 degrees C for 10 min led to the best results. The authors report that longer pepsin treatments led to some tissue destruction, and longer HIER resulted in bleb formation underneath the membrane, however, the blebs did not affect subsequent IHC. HIER solution had no effects on CD20 staining, but CD30 staining was better using the Dako Target Retrieval solution as opposed to the Dako Cytomation retrieval solution. For CD20, the best results were obtained with 16 h of antigen retrieval, but for CD30, 42 h were necessary. The quality of CD20 and CD30 IHC staining was comparable in tissues mounted on PEN and glass slides.
Biospecimens
TissueLymph NodePreservation Types
FormalinDiagnoses
NeoplasticLymphomaPlatforms
MorphologyMacroscopic observationProteinImmunohistochemistryPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Aliquots and Components Type of slide GlassNot pretreatedPENPretreatedAnalyte Extraction and Purification Antigen retrieval 10 min15 min16 h20 min24 h42 h48 h60 degrees C in Dako Cytomation retrieval solution60 degrees C in Dako Retrieval solutionPepsin in vertical bathPepsin pipetted on horizontal slideImmunohistochemistry Specific Antibody dilution/concentration 1:201:2001:4001:50Immunohistochemistry Specific Targeted peptide/protein CD20CD30
Purpose
The purpose of this study was to determine the effects of using ILAM rather than H&E guided LAM for cell capture on DNA yield, quality and methylation status of lymphomas. DNA was extracted using the QIAamp DNA micro kit.
Summary of Findings
Manual microdissection of tumor cells was successful using all three systems, but the LMD 6000 and PALM MicroBeam allowed for easier cell recovery and the software with the Arcturus XT was better suited for automatic cell recognition when IHC was visualized using DAB. 9-64% as much DNA was obtained from 75,000 ILAM tumor cells than from the same number of H&E guided LAM cells. However, amplification of 152 bp and 268 bp fragments of beta-globin was similarly successful from LAM and ILAM cells, and amplification of a 676 bp fragment of beta-globin was not possible with DNA obtained from ILAM or LAM cells. CpG methylation was strongly correlated between the ILAM and LAM stained cells (r>0.94). Of 1505 identified methylation sites, 1501 had the same status in ILAM and LAM cells, but 4 targets did show significant differences in methylation (p<0.0001-0.044).
Biospecimens
TissueLymph NodePreservation Types
FormalinDiagnoses
NeoplasticLymphomaPlatforms
DNAPCRDNASpectrophotometryMorphologyH-and-E microscopyProteinImmunohistochemistryPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Aliquots and Components Cell capture method Arcturus XTLeica LMD 6000PALM MicroBeamPCR Specific Length of gene fragment 152 bp268 bp676 bpPCR Specific Targeted nucleic acid Beta-globinPCR Specific Type of tissue stain H&E stainedImmunostained