Skip to main content

Immunohistochemical staining of plastic embedded bone marrow trephine biopsy specimens after microwave heating.

McCluggage WG, Roddy S, Whiteside C, Burton J, McBride H, Maxwell P, Bharucha H

Publication: J Clin Pathol (1995) • Vol 48 • Page 840-4PMID: 7490318View on PubMed

Purpose

The purpose of this paper was to determine the effects of processing methods involving different embedding materials on immunohistochemical (IHC) staining and morphological preservation in bone marrow trephine biopsies.

Conclusion

19 of 22 antibodies gave IHC staining results that were comparable between acetic acid-formol saline-fixed, paraffin-embedded, decalcified bone marrow trephine biopsies and those that were formalin-fixed, embedded in plastic (Polarbed 812 epoxy resin), and treated by microwave heating in citrate buffer prior to immunostaining. CD20 immunostaining was superior in formalin-fixed plastic-embedded specimens, while neutrophil elastase and CD61 immunostaining were superior in acetic-acid formol saline-fixed paraffin-embedded specimens. Cellular morphology was better in formalin-fixed plastic-embedded specimens which were able to be cut into 1 uM sections as opposed to 5 uM sections.

Studies (1)

Purpose

The purpose of this study was to determine the effects of fixation method, embedding material, decalcification, and antigen retrieval on IHC staining and morphological preservation in bone marrow trephine biopsies. Specimens designated for paraffin embedding were fixed in 3% acetic acid in 10% unbuffered formol saline for 1.5-3 h and decalcified with EDTA. Specimens designated for plastic embedding were fixed overnight in 10% neutral buffered formalin and underwent antigen retrieval prior to staining.

Summary of Findings

19 of 22 antibodies gave IHC staining results that were comparable between acetic acid-formol saline-fixed, paraffin-embedded, decalcified bone marrow trephine biopsies and those that were formalin-fixed, embedded in plastic (Polarbed 812 epoxy resin), and treated by microwave heating in citrate buffer prior to immunostaining. CD20 immunostaining was superior in formalin-fixed plastic-embedded specimens, while neutrophil elastase and CD61 immunostaining were superior in acetic acid-formol saline-fixed paraffin-embedded specimens. Cellular morphology was better in formalin-fixed plastic-embedded specimens which were able to be cut into 1 uM sections as opposed to 5 uM sections.

  • Biospecimens

    TissueBone Marrow
  • Preservation Types

    FormalinOther Preservative
  • Diagnoses

    Not specified
    Normal
    NeoplasticCarcinoma
    NeoplasticLymphoma
  • Platforms

    ProteinImmunohistochemistry
    MorphologyH-and-E microscopy
    MorphologyLight microscopy
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen Aliquots and ComponentsType of slide
    1 uM section
    5 uM section
    Biospecimen PreservationEmbedding medium
    Epoxy resin
    Paraffin
    Biospecimen PreservationType of fixation/preservation
    Acetic acid-formol saline
    Formalin (buffered)
    Analyte Extraction and PurificationAntigen retrieval
    Microwaved in citrate buffer
    None
    Analyte Extraction and PurificationDecalcification solution/ duration
    EDTA pH 7.0
    None