Decreases in albumin/creatinine and N-acetylglucosaminidase/creatinine ratios in urine samples stored at -20 degrees C.
Manley SE, Burton ME, Fisher KE, Cull CA, Turner RC
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine the effects of storage of urine specimens at -20 degrees C on albumin, N-acetylglucosaminidase, and creatinine levels. Specimens were first assayed after up to 7 d of storage at 4 degrees C, and then again after 6 months or 2 y at -20 degrees C.
Summary of Findings
Albumin and N-acetylglucosaminidase levels significantly decreased after storage at -20 degrees C for 6 months or 2 y compared to initial measurements taken in the same specimens after <7 d at 4 degrees C (p<0.001 for both analytes). Specimens with lower initial albumin concentrations showed proportionally larger decreases in albumin after frozen storage. Further, albumin and N-acetylglucosaminidase losses were greater after storage for 2 y compared to losses after 6 months of storage. Creatinine levels were slightly but significantly decreased after 6 months of storage at -20 degrees C (p<0.05), and levels were further reduced after storage for 2 y (p<0.001). Unlike albumin, reduction in creatinine levels was not dependent on initial concentration. Albumin/creatinine and N-acetylglucosaminidase/creatinine ratios were reduced after frozen storage, with greater effects on ratios initially at the lower end of the range.
Biospecimens
FluidUrinePreservation Types
Other PreservativeFrozenDiagnoses
Diabetes Type 2Platforms
ProteinClinical chemistry/auto analyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Preservation Type of fixation/preservation FrozenRefrigerationThiomersalStorage Storage duration 2 y6 monthsUp to 7 dStorage Storage temperature -20 degrees C4 degrees CClinical chemistry/auto analyzer Specific Targeted peptide/protein AlbuminCreatinineN-acetylglucosaminidase