Comparison of simultaneously obtained arterial and capillary blood gases in pediatric intensive care unit patients.

Harrison AM, Lynch JM, Dean JM, Witte MK

Publication: Crit Care Med (1997) • Vol 25 • Page 1904-8PMID: 9366777View on PubMed

Purpose

The purpose of this paper was to determine the effects of collecting capillary rather than arterial blood on blood gas determination.

Conclusion

Generally, pH and partial pressure carbon dioxide (pCO2) in capillary blood represented values found in arterial blood and accurately estimated acidosis and hypercarbia, but partial pressure oxygen was lower in capillary specimens than arterial specimens.

Studies (1)

Purpose

The purpose of this study was to compare blood gas levels in capillary and arterial blood specimens from children with an indwelling arterial catheter. Arterial and capillary specimens were collected simultaneously, placed on ice, and analyzed immediately.

Summary of Findings

pH levels were highly correlated between arterial and capillary specimens (r=0.903), but there was an average non-significant bias of 0.009 of the capillary specimen pH to be lower than the arterial specimen pH. Importantly, all 6 patients with an arterial blood pH of less than 7.35 had a capillary blood pH of less than 7.35, but 3 patients with an arterial pH of more than 7.35 had a capillary pH of less than 7.35. While the pCO2 was highly correlated between arterial and capillary specimen (r=0.955), pCO2 was generally higher in capillary specimens than in the arterial specimens with an average bias of 0.21 kPa. For most patients the difference in pCO2 was small, but for 2 of the 50 patients the pCO2 differed by more than 0.87 kPa. Importantly, all cases of hypercarbia identified from arterial blood were also identified in capillary blood, but 6 additional cases were found using capillary blood. The partial pressure oxygen was moderately correlated between capillary and arterial specimens, with capillary specimen levels lower than arterial specimens and an average bias of 3.3 kPa, but in 42 of 50 patients, there was a difference of more then 0.87 kPa between capillary and arterial pO2.

  • Biospecimens

    FluidBlood
  • Preservation Types

    Other PreservativeNone (Fresh)
  • Diagnoses

    Other diagnoses
    Not specified
  • Platforms

    GasClinical chemistry/auto analyzer
    Small moleculepH
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    PreaquisitionBiomarker level
    pCO2 <6.1 kPa
    pCO2 >6.1 kPa
    pH <7.35
    pH >7.35
    Biospecimen AcquisitionAnatomical location of blood draw
    Artery
    Capillary