The purpose of this study was to determine the effects of collecting fingerstick plasma rather than venous serum and transferring venous serum to a capillary tube on cholesterol levels. Fingerstick specimens were collected in capillary tubes with heparin and centrifuged within 5 min while venous serum was allowed to clot in glass tubes without anticoagulant for 30 min. After centrifugation, plasma and serum were refrigerated on ice for up to 3 h before analysis, at which point an aliquot of the serum was transferred to a capillary tube.
Summary of Findings
Cholesterol levels in fingerstick plasma were highly correlated with levels in venous serum prior to (r=0.95) and after transfer to a capillary tube (r=0.95), however, cholesterol levels were higher in the fingerstick plasma, with a mean bias of 3.6% compared to venous serum in a glass tube, and 2.4% compared to venous serum in a capillary tube. The amount of the bias was inversely proportional to the cholesterol levels. Cholesterol levels were highly correlated between venous serum specimens before and after transfer to a capillary tube (r=0.98), but there was a 1.1% positive bias in the specimens transferred to the capillary tube.
Biospecimens
FluidPlasmaFluidSerumFluidBloodPreservation Types
Other PreservativeNone (Fresh)Diagnoses
Not specifiedPlatforms
SteroidClinical chemistry/auto analyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Anatomical location of blood draw CapillaryVeinBiospecimen Acquisition Method of fluid acquisition Finger/heel prick samplingVenipunctureBiospecimen Aliquots and Components Blood and blood products PlasmaSerumStorage Type of storage container Capillary tubeGlass tube