Comparison of the effects of dry and liquid heparin on neonatal arterial blood gases.
Gayed AM, Marino ME, Dolanski EA
Purpose
Conclusion
Studies (2)
Purpose
The purpose of this study was to determine the effects of using vaporized versus liquid heparin on arterial blood gas analysis in neonates. 35 neonatal arterial blood specimens were collected from umbilical or peripheral arterial catheters into tubes containing liquid heparin or dry vaporized heparin.
Summary of Findings
Neonatal blood that was anticoagulated with liquid heparin had lower PaCO2 (p<0.00005) and carbon dioxide (p<0.00005) content than specimens anticoagulated with vaporized heparin. There were no effects of using vaporized rather than liquid heparin on PaO2, oxygen saturation or pH in neonatal blood.
Biospecimens
FluidBloodPreservation Types
None (Fresh)Diagnoses
PregnantPlatforms
GasClinical chemistry/auto analyzerSmall moleculepHPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Anticoagulant HeparinMultiple forms evaluated
Purpose
Summary of Findings
Biospecimens
FluidBloodPreservation Types
None (Fresh)Diagnoses
NormalPlatforms
GasClinical chemistry/auto analyzerSmall moleculepHPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Anticoagulant HeparinNoneBiospecimen Aliquots and Components Biospecimen components 0.1 mL heparin0.1 mL saline0.3 mL heparin0.3 mL saline0.5 mL heparin0.5 mL salineNo added saline or heparin